Chirobiotic V Versus Chiralpak ID for the Enantioselective Chromatographic Separation of Chloroquine: Stability and Validation Study
Related Experiment Video
Updated: Jan 28, 2026

Development of Heterogeneous Enantioselective Catalysts using Chiral Metal-Organic Frameworks MOFs
Published on: January 17, 2020
Priscila Aburachid Cardoso1, Diego Beltrão Pereira1, Mohammed Farrag El-Behairy2
1Departamento de Produtos Farmacêuticos, Faculdade de Farmácia, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil.
Abstract:
Chloroquine is a chiral antimalarial drug and demonstrates enantioselective pharmacodynamic and pharmacokinetic properties. However, this drug is administered as racemate. The knowledge of stereoselective aspects of these agents may be useful to better understand their mechanisms of action and to optimize their safety and/or clinical efficacy. In this study, an enantioselective analytical method for the quantification of chloroquine enantiomers was developed using HPLC-UV. The chromatographic conditions were: Chirobiotic V column (100 × 2.1 mm, 5 μm) at 25°C, mobile phase containing methanol:acetic acid:triethylamine (100:0.12:0.12), flow rate 1 mL/min, injection volume 10 μL and detection at 258 nm. The validation parameters evaluated were selectivity, linearity, precision, accuracy, and robustness. In addition, a stability study after forced degradation of chloroquine enantiomers was performed. The enantioseparation of chloroquine using a polysaccharide-based chiral stationary phase (Chiralpak ID) at different mobile phase composition was evaluated and the chromatographic performance of both columns was compared. Thus, a stability-indicating chiral analytical method was developed and fully validated, allowing the separation of chloroquine enantiomers and its degradation products in tablets available in Brazil.
More Related Videos
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Reliability and Validity
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
Nuclear Stability
To hold positively charged protons together...