Fast gas chromatography-atmospheric pressure (photo)ionization mass spectrometry of polybrominated diphenylether
Robert A Di Lorenzo1, Vladislav V Lobodin2, Jack Cochran3
1Mouse Imaging Centre, The Hospital for Sick Children, 25 Orde Street, Toronto, ON, M5T 3H7, Canada.
Abstract:
Gas chromatography (GC) and mass spectrometry (MS) are powerful, complementary techniques for the analysis of environmental toxicants. Currently, most GC-MS instruments employ electron ionization under vacuum, but the concept of coupling GC to atmospheric pressure ionization (API) is attracting revitalized interest. API conditions are inherently compatible with a wide range of ionization techniques as well high carrier gas flows that enable fast GC separations. This study reports on the application of atmospheric pressure chemical ionization (APCI) and a custom-built photoionization (APPI) source for the GC-MS analysis of polybrominated diphenyl ethers (PBDEs), a ubiquitous class of flame retardants. Photoionization of PBDEs resulted in the abundant formation of molecular ions M•+ with very little fragmentation. Some photo-oxidation was observed, which differentiated critical BDE isomers. Formation of protonated molecules [M+H]+ did not occur in GC-APPI because the ionization energy of H2O (clusters) exceeds the energy of the ionizing photons. Avoiding mixed-mode ionization is a major advantage of APPI over APCI, which requires careful control of the source conditions. A fast GC-API-MS method was developed using helium and nitrogen carrier gases that provides good separation of critical isomers (BDE-49/71) and elution of BDE 209 in less than 7 min (with He) and 15 min (with N2). It will be shown that the GC-APPI and GC-APCI methods match the sensitivity and improve upon the selectivity and throughput of established methods for the analysis of PBDEs using standard reference materials (NIST SRM 1944 and SRM 2585) and selected environmental samples.
More Related Videos
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chemical Ionization (CI) Mass Spectrometry
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...