Related Experiment Video
Updated: Jan 28, 2026

Uracil-DNA Glycosylase Assay by Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry Analysis
Published on: April 22, 2022
The proteome analysis of rat platelet with nano-liquid chromatography-matrix-assisted laser desorption/ionization
A Gromotowicz-Poplawska1, J Kasprzyk2, N Marcinczyk3
1Department of Biopharmacy, Faculty of Pharmacy with the Division of Laboratory Medicine, Medical University of Bialystok, Bialystok, Poland. anna.gromotowicz@umb.edu.pl.
Abstract:
Recently, the proteomic analysis has become an ideal tool to study the structure and function of platelets. We proposed a nano-liquid chromatography (nano-LC) technique coupled off-line with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/TOF-MS) for rat platelet proteome analysis. In this study, we attempted to analyze the rat platelet proteome in two different subcellular fractions: cytosol and membrane. Platelet-rich plasma was collected from healthy rats. The platelet samples were extracted with Subcellular Proteome Extraction Kit to collect subcellular compartments. For further investigations, platelet lysate, cytosol and membrane fractions were used. Enzymatic digestion of proteins was performed using Filter Aided Sample Preparation method with trypsin as a proteolytic enzyme. Tryptic peptides were analyzed using nano-LC-MALDI-TOF/TOF-MS. Platelet proteins identification was performed using the Mascot engine. We identified 238 proteins in the platelet lysate, 210 in the cytosol, and 148 in the membrane fraction. Among them, 45 were unique for platelet lysate, 55 for cytosol, and 34 for the membrane fraction. The gene ontology analysis showed that there were differences in the proteome of cytosol and membrane fractions related to the molecular functions, i.e. coagulative activity. Our results may suggest that the membrane or cytosol location of the proteins with coagulative activity may be responsible for the acute or delayed platelet response to an agonist. The nano-LC-MALDI-TOF/TOF-MS method can be used for identifying proteins of subcellular fraction in rat platelets.
More Related Videos
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
08:51Profiling of Permethylated Mucin O-glycans Using Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry
Published on: June 20, 2025
Related Concept Videos
Matrix-Assisted Laser Desorption Ionization (MALDI)
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: