Related Experiment Video
Updated: Jan 28, 2026

Automated Robotic Liquid Handling Assembly of Modular DNA Devices
Published on: December 1, 2017
Automated online coupling of robot-assisted single drop microextraction and liquid chromatography
Deyber Arley Vargas Medina1, Luis Felipe Rodríguez Cabal1, Guilherme Miola Titato1
1São Carlos Institute of Chemistry, University of São Paulo, 13566-590, São Carlos, SP, Brazil.
Abstract:
A high-throughput and innovative setup has been developed to automate the online integration of single drop microextraction (SDME), liquid chromatography (LC) and high-resolution mass spectrometry (QqToF). SDME and LC were online hyphenated for the first time. SDME was carried out by a lab-made cartesian robot actuating a 100 μL syringe, equipped with a three-way solenoid microvalve that allowed the online transference of the enriched extract to the chromatographic system, through a six-port switching valve. The complete method, including the synchronized robot action, valves, and the analytical instruments, was controlled by an Arduino Mega board. The merits of the proposed setup were demonstrated by the triazines determination in coconut water samples. The most relevant extraction parameters, such as drop size, exposure time, stirring effect, salt addition and pH were systematically investigated. Under optimized conditions (60 μL drop volume and 10 min extraction time), the LC-UV enrichment factors (EF) and the extraction recoveries (ER) ranged between 15.2-18.4 and 11.4-13.8%, respectively. Using the SDME-LC-MS setup, the linear range, detection limit (S/N = 3) and precision (RSD, n = 6 at 0.25 μg L-1 level of concentration) were 0.25-25 μg L-1, 0.10 μg L-1 and 16.8% for simazine; 0.25-25 μg L-1, 0.05 μg L-1 and 14.7% for atrazine; and 0.25-25 μg L-1, 0.05 μg L-1 and 18.5% for propazine, respectively. Although none of the analytes were detected in the evaluated commercial samples, the results indicate that the proposed online SDME-LC setup is a competitive analytical strategy for the determination of target organic compounds in complex matrices.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...

