Related Experiment Video For CT imaging spectroscopy
Updated: Jan 28, 2026

Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma
Published on: January 9, 2019
Spectral CT Imaging in the Differential Diagnosis of Small Bowel Adenocarcinoma From Primary Small Intestinal
Chuang-Bo Yang1, Nan Yu2, Yong-Jun Jian3
1Department of Radiology, Affiliated Hospital of Xi'an Jiaotong University, Yanta western road 277#, Xi'an, Shaanxi, China; Department of Radiology, Affiliated Hospital of Shaanxi University of Chinese Medicine, Shaanxi, China.
Purpose:
To investigate the value of dual-energy spectral computed tomography (CT) imaging in the differential diagnosis of small bowel adenocarcinoma (SBA) from primary small intestinal lymphoma (PSIL).
Materials And Methods:
We retrospectively analyzed the images of 27 SBA cases and 15 PSIL cases. These patients underwent spectral CT imaging in the arterial phase (AP) and venous phase (VP). CT attenuation values of tumors at different energy levels were measured to generate spectral attenuation curve and to calculate curve slope (λHU). Iodine concentration (IC) in tumors at AP and VP were measured and normalized to that of aorta as normalized iodine concentration (NIC). Independent samples t test was used to analyze the spectral CT parameters; Receiver operating characteristic curves were generated to evaluate the diagnostic efficacy of each parameter.
Results:
There were significant differences between SBA and PSIL in IC (2.09 ± 0.71 vs 1.33 ± 0.15 mg/ml), NIC (0.20 ± 0.06 vs 0.13 ± 0.02) and slope (λHU) (2.78 ± 1.06 vs 1.86 ± 0.30) in AP and (1.86 ± 0.68 vs 1.37 ± 0.18 mg/ml for IC; 0.47 ± 0.13 vs 0.33 ± 0.02 for NIC and 2.00 ± 0.56 vs 1.50 ± 0.26 for λHU) in VP (all p < 0.05). For the CT value measurement, there were significant differences between SBA and PSIL in the 40-60keV energy range (p < 0.05), but not in the 70-140keV range (p > 0.05). Using 1.38 mg/ml as a threshold value for iodine concentration at AP, one could obtain the area-under-curve of 0.93 for receiver operating characteristic study and sensitivity of 94% and specificity of 85% for differentiating SBA from PSIL. The sensitivity and specificity values were significantly higher than the respective values of 62% and 60% with the conventional CT numbers at 70keV.
Conclusion:
Quantitative parameters obtained in spectral CT, especially iodine concentration in AP, provide high accuracy for differentiating SBA from PSIL.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Anatomy of the Intestines
Small Intestines
The small intestine is an ~7 meter-long tube with an inner diameter of just 2.5 cm. Since most nutrients are absorbed here, the inner lining of the...
Nursing Diagnosis
The nursing diagnosis focuses on evidence-based...
Chronic Bowel Disorders: Introduction
Irritable Bowel Syndrome (IBS) is a common disorder affecting the gastrointestinal tract. The distinctive feature is recurrent abdominal pain associated with altered bowel movements, manifesting as constipation, diarrhea, or fluctuating between both. The...

