Objective measurement of tummy time in infants (0-6 months): A validation study
Lyndel Hewitt1, Rebecca M Stanley1, Dylan Cliff1
1Early Start, Faculty of Social Sciences and Illawarra Health and Medical Research Institute, University of Wollongong, Northfields Avenue, Wollongong, New South Wales, Australia.
Insights
Objective measurement of infant tummy time is now possible using wearable devices. This study found GENEActiv and ActiGraph (hip) devices accurately track prone positioning, aiding adherence to movement guidelines.
Area of Science:
- Pediatric Health
- Movement Science
- Wearable Technology
Background:
- Current infant movement guidelines recommend 30 minutes of daily tummy time.
- No validated objective tools exist to measure infant tummy time accurately.
- Accurate measurement is crucial for monitoring adherence to health recommendations.
Purpose of the Study:
- To assess the practicality of using wearable devices for objective infant tummy time measurement.
- To evaluate the accuracy of algorithms for predicting prone posture using these devices.
- To inform the development of tools for monitoring infant movement guidelines.
Main Methods:
- Thirty-two infants (4-25 weeks) wore MonBaby, GENEActiv, and ActiGraph devices.
- Infants were placed in 12 different positions for 3 minutes each.
- Direct observation served as the criterion measure for posture validation.
- Parental feedback on device practicality was collected via questionnaire.
Main Results:
- Algorithms achieved high accuracy: 79-95% for tummy time and 96-100% for non-prone positions.
- GENEActiv and ActiGraph (hip) demonstrated the best accuracy for prone and non-prone positions, respectively.
- Most parents found the devices practical and feasible for home use, preferring MonBaby.
Conclusions:
- Wearable devices, particularly GENEActiv and ActiGraph (hip), offer acceptable accuracy for objectively measuring infant tummy time (prone on floor).
- These validated tools can aid in monitoring infant positioning and adherence to 24-hour movement guidelines.
- Objective measurement is key to understanding and promoting healthy early childhood movement behaviors.
Abstract:
The 2017 Australian and Canadian 24-hour movement guidelines recommend infants receive 30 minutes of tummy time daily. Currently, there are no validated objective measurement tools or devices to assess tummy time. The purpose of this study was to: 1) test the practicality of using devices on infants as an objective measure of tummy time, and 2) test the accuracy of developed algorithms and cut-points for predicting prone posture. Thirty-two healthy infants aged 4 to 25 weeks completed a protocol of 12 positions. Infants were placed in each position for 3 minutes while wearing a MonBaby (chest), GENEActiv (right hip) and two ActiGraphs (right hip and ankle). Direct observation was the criterion measure. The accuracy of the algorithms or cut-points to predict prone on floor, non-prone and prone supported positions were analyzed. Parents also completed a practicality questionnaire. Algorithms and cut-points to classify posture using devices from MonBaby, GENEActiv and ActiGraph (hip and ankle) were 79%, 95%, 90% and 88% accurate at defining tummy time and 100%, 98%, 100% and 96% accurate at defining non-prone positions, respectively. GENEActiv had the smallest mean difference and limits of agreement (-8.4s, limits of agreement [LoA]: -78.2 to 61.3s) for the prone on floor positions and ActiGraph Hip had the smallest mean difference and LoA for the non-prone positions (-0.2s, LoA: -1.2 to 0.9s). The majority of parents agreed all devices were practical and feasible to use with MonBaby being the preferred device. The evaluated algorithms and cut-points for GENEActiv and ActiGraph (hip) are of acceptable accuracy to objectively measure tummy time (time spent prone on floor). Accurate measurement of infant positioning practices will be important in the observation of 24-hour movement guidelines in the early years.
Related Concept Videos
Reliability and Validity
Velocity of an Object
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Potential Due to a Polarized Object
Potential Due to a Magnetized Object
The vector...