Related Experiment Video
Updated: Jan 28, 2026

Preparation of Mitochondria from Ovarian Cancer Tissues and Control Ovarian Tissues for Quantitative Proteomics Analysis
Published on: November 18, 2019
A faster PISTOL for 1 H MR-based quantitative tissue oximetry
Rohini Vidya Shankar1, Vikram D Kodibagkar1
1School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ, USA.
Abstract:
Quantitative mapping of oxygen tension (pO2 ), noninvasively, could potentially be beneficial in cancer and stroke therapy for monitoring therapy and predicting response to certain therapies. Intracellular pO2 measurements may also prove useful in tracking the health of labeled cells and understanding the dynamics of cell therapy in vivo. Proton Imaging of Siloxanes to map Tissue Oxygenation Levels (PISTOL) is a relatively new oximetry technique that measures the T1 of administered siloxanes such as hexamethyldisiloxane (HMDSO), to map the tissue pO2 at various locations with a temporal resolution of 3.5 minutes. We have now developed a siloxane-selective Look-Locker imaging sequence equipped with an echo planar imaging (EPI) readout to accelerate PISTOL acquisitions. The new tissue oximetry sequence, referred to as PISTOL-LL, enables the mapping of HMDSO T1 , and hence tissue pO2 in under one minute. PISTOL-LL was tested and compared with PISTOL in vitro and in vivo. Both sequences were used to record dynamic changes in pO2 of the rat thigh muscle (healthy Fischer rats, n = 6), and showed similar results (P > 0.05) as the other, with each sequence reporting a significant increase in pO2 (P < 0.05) under hyperoxia compared with steady state normoxia. This study demonstrates the ability of the new sequence in rapidly and accurately mapping the pO2 changes and accelerating quantitative 1 H MR tissue oximetry by approximately 4-fold. The faster PISTOL-LL technique could enable dynamic 1 H oximetry with higher temporal resolution for assesing tissue oxygentation and tracking the health of transplanted cells labeled with siloxane-based probes. With minor modifications, this sequence can be useful for 19 F applications as well.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
SN1 Reaction: Stereochemistry
In the first step of an SN1 reaction, the bond between the electrophilic carbon and the leaving group ionizes to generate the carbocation intermediate. The second step of the mechanism is the nucleophilic attack.
In the formed carbocation, the positively charged carbon is sp2 hybridized with a trigonal planar geometry. As all the three substituents lie on the same plane, a plane of symmetry for the...
SN1 Reaction: Kinetics
However, Sir Christopher Ingold and Edward D. Hughes, who studied the kinetics of various nucleophilic substitution reactions, noticed that a tertiary alkyl halide does undergo a nucleophilic substitution reaction in the presence of a weak nucleophile. While studying the substitution...
SN1 Reaction: Mechanism
Firstly, the haloalkane ionizes to generate a carbocation intermediate and a halide ion. This heterolytic cleavage is highly endothermic with large activation energy. The ionization of the substrate, facilitated by a...
Acidity of 1-Alkynes
The acidic strength of hydrocarbons follows the order: Alkynes > Alkenes > Alkanes. The strength of an acid is commonly expressed in units of pKa — the lower the pKa, the stronger the acid. Among the hydrocarbons, terminal alkynes have lower pKa values and are, therefore, more acidic. For example, the pKa values for ethane, ethene, and acetylene are 51, 44, and 25, respectively, as shown here.
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...

