Related Experiment Video
Updated: Jan 28, 2026

Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
Published on: September 27, 2018
First Detection of Phytoplasmas in Rhododendron in the Czech Republic
J Mertelik1, K Kloudova1, P Vanc1
1Research Institute for Landscape and Ornamental Gardening, 252 43 Pruhonice, Czech Republic.
Abstract:
A 10-year-old plant of rhododendron ('Cunningham's White' PS986) with leaf malformation and variegation was observed in Prague in 1997. This plant was micropropagated, and regenerants with severe, mild and no symptoms were obtained. Phytoplasma infection was detected using nested polymerase chain reaction (PCR) in the original PS986 plant and the symptomatic regenerants but not in nonsymptomatic plants. During 2002, phytoplasmas were also detected in rhododendron hybrids, PS2716 and PS2439, grown in Pruhonice that showed similar symptoms as the plant observed in Prague. In nested PCR, performed as described previously (1), primer pairs R16F1/R16R0 and R16F2/R16R2 were used. The phytoplasmas detected were classified by restriction fragment length polymorphism analysis using R16F2/R16R2 PCR fragments. Following digestion with restriction endonuclease MseI (Promega, Madison, WI), the restriction profiles obtained were identical with the pattern of the stolbur phytoplasma group (16SrXII group) as determined previously (2). To our knowledge, this is the first finding of stolbur-type phytoplasma in rhododendron worldwide. References: (1) R. Fialova et al. Plant Prot. Sci. 39(1):7, 2003. (2) I.-M Lee et al. Int. J. Syst. Bacteriol. 48:1153,1998.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...

