Related Experiment Video
Updated: Jan 28, 2026

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
A nonenzymatic electrochemical glucose sensor based on molecularly imprinted polymer and its application in measuring
Alassane Diouf1, Benachir Bouchikhi2, Nezha El Bari3
1Sensor Electronic & Instrumentation Group, Department of Physics, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, Meknes, Morocco; Biotechnology Agroalimentary and Biomedical Analysis Group, Department of Biology, Faculty of Sciences, Moulay Ismaïl University, B.P. 11201, Zitoune, 50003 Meknes, Morocco.
Abstract:
Diabetes mellitus (DM) is often diagnosed by invasive or enzymatic methods being progressively somewhat undesirable. If salivary glucose (SG) level correlates with blood glucose (BG), it could be useful for early DM detection. In this work, a molecular imprinted polymer (MIP) approach was used to develop an electrochemical non-enzymatic sensor to determine SG in micro-molar levels. The MIP based Screen printed gold electrode (Au-SPE) was prepared by electropolymerizing Acrylamide/Bis-Acrylamide (AAM/NNMBA) in the presence of glucose (G) as a template. The Cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques were employed for the electrochemical measurements with Ferri/Ferrocyanide as redox probe in phosphate buffer saline. Morphological characterizations of the elaborated sensors were performed by using atomic force microscopy (AFM) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Important parameters influencing the MIP sensor performances such as extraction, incubation time, potential range and number of CV cycles, were studied and optimized. Under optimum conditions, the sensor could effectively detect glucose avoiding interferences of structural similar substances like lactose and sucrose. In a working range from 0.5 to 50 μg/mL, it exhibits a detection and quantification limits of 0.59 μg/mL and 1.9 μg/mL, respectively. Additionally, the real saliva glucose determination was compared to those of finger prick blood with satisfactory results (R2 = 0.99) by using partial least squares (PLS) statistical technique. Correspondingly, this work has demonstrated a cheap, simple and effective sensing platform for non-enzymatic glucose detection thus making it a promising tool for future evolution of accurate and reliable non-invasive DM diagnosis.
Related Concept Videos
Glucose Homeostasis: Regulation of Blood Glucose
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
Glucose Transporters
Facilitated diffusion-glucose transporters (GLUTs) are encoded by the solute-linked carrier (SLC) family 2, subfamily A gene family, or SLC2A. The 14 GLUT protein members are distributed into three classes:
Imprinting
Glucose Absorption Into the Small Intestine
Hormones Regulating Blood Glucose
In addition to accelerating glucose uptake and utilization, insulin has...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...