Related Experiment Video
Updated: Jan 28, 2026

A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
Gold-Plated Electrode with High Scratch Strength for Electrophysiological Recordings
Mohaddeseh Vafaiee1, Manouchehr Vossoughi2,3, Raheleh Mohammadpour1
1Institute for Nanoscience and Nanotechnology, Sharif university of Technology, Tehran, Iran.
Abstract:
Multi electrode arrays (MEA) have been exploited in different electrophysiological applications. In neurological applications, MEAs are the vital interfaces between neurons and the electronic circuits with dual role; transmitting electric signal to the neurons and converting neural activity to the electric signal. Since the performance of the electrodes has a direct effect on the quality of the recorded neuronal signal, as well as the stimulation, the true choice of electrode material for MEA is crucial. Gold is one of the best candidates for fabrication of MEAs due to its high electrical conductivity, biocompatibility and good chemical stability. However, noble metals such as gold do not adhere well to the glass substrate. Consequently while exposing to the water, gold films are damaged, which impose limitations in the exploiting of gold thin films as the electrode. In this paper, a simple and cost effective method for the fabrication of gold electrode arrays is proposed. Using various mechanical (adhesion test and scratch strength), morphological (AFM and SEM) and electrochemical methods, the fabricated electrodes are characterized. The results show that the fabricated electrode arrays have significantly high scratch strength and stability within the aqueous medium. In addition, the electrical properties of the electrodes have been improved. The proposed electrodes have the potential to be exploited in other applications including electronics, electrochemistry, and biosensors.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
Standard Electrode Potentials
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...