Accurate and rapid CT image segmentation of the eyes and surrounding organs for precise radiotherapy
Yao Sun1,2, Huabei Shi1,2, Shuo Zhang1,2
1Department of Biomedical Engineering, Tsinghua University, Beijing, 100084, China.
Objective:
The precise segmentation of organs at risk (OARs) is of importance for improving therapeutic outcomes and reducing injuries of patients undergoing radiotherapy. In this study, we developed a new approach for accurate computed tomography (CT) image segmentation of the eyes and surrounding organs, which is first locating then segmentation (FLTS).
Methods:
The FLTS approach was composed of two steps: (a) classification of CT images using convolutional neural networks (CNN), and (b) segmentation of the eyes and surrounding organs using modified U-shape networks. In order to obtain optimal performance, we enhanced our training datasets by random jitter and rotation.
Results:
This model was trained and verified using the clinical datasets that were delineated by experienced physicians. The dice similarity coefficient (DSC) was employed to evaluate the performance of our segmentation method. The average DSCs for the segmentation of the pituitary, left eye, right eye, left eye lens, right eye lens, left optic nerve, and right optic nerve were 90%, 94%, 93.5%, 84.5%, 84.3%, 80.3%, and 82.2%, respectively.
Conclusion:
We developed a new network-based approach for rapid and accurate CT image segmentation of the eyes and surrounding organs. This method is accurate and efficient, and is suitable for clinical use.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Uncertainty in Measurement: Accuracy and Precision
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Accuracy and Precision
Levels of Organization
Molecules Are Composed of Atoms, and Biomolecules Are Assembled from Molecules:
The most basic levels include atoms, molecules, and biomolecules. Atoms, the smallest unit of ordinary matter, are composed of a nucleus and electrons. Molecules...