Related Experiment Video
Updated: Jan 28, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Trends in total hip arthroplasty
Wade D Aumiller1, Thomas M Kleuser
1At the time this article was written, Wade D. Aumiller was a student in the PA program at the University of Texas Pan American. He now practices in neurosurgery with Bianco Brain and Spine LLCP in Arlington, Tex. Thomas M. Kleuser was a practicing orthopedic surgeon in Fort Worth, Tex., when this article was written, and is now retired. The authors have disclosed no potential conflicts of interest, financial or otherwise.
Highly cross-linked polyethylene (HXLPE) is now the standard for hip replacements, improving outcomes. The article also examines potential issues with metal-on-metal hip implants in patients without symptoms.
Area of Science:
- Orthopedic surgery
- Biomaterials science
Background:
- Total hip arthroplasty (THA) is a common procedure for hip joint restoration.
- Advancements in bearing materials are crucial for improving THA longevity and patient outcomes.
- Concerns regarding metal ion release and adverse reactions have been raised with certain hip implant designs.
Purpose of the Study:
- To review the current developments in total hip arthroplasty focusing on highly cross-linked polyethylene (HXLPE) as a standard bearing material.
- To discuss the clinical implications and pathological considerations of metal-on-metal hip prostheses, particularly in asymptomatic individuals.
Main Methods:
- Literature review of recent advancements in hip arthroplasty materials and designs.
- Analysis of studies investigating the performance and complications of highly cross-linked polyethylene (HXLPE) liners.
- Examination of research on the long-term effects and pathology associated with metal-on-metal hip prostheses.
Main Results:
- Highly cross-linked polyethylene (HXLPE) has emerged as the preferred material for acetabular cup articulation surfaces in total hip arthroplasty due to its enhanced wear resistance.
- Metal-on-metal hip prostheses present potential risks, including adverse local tissue reactions and systemic metal ion exposure, even in asymptomatic patients.
Conclusions:
- The adoption of highly cross-linked polyethylene (HXLPE) represents a significant advancement in total hip arthroplasty, offering improved durability.
- Careful consideration and monitoring are warranted for patients with metal-on-metal hip prostheses due to potential long-term adverse effects.
Related Concept Videos
Current Trends in Nursing I
Current Trends in Nursing II
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Trends in Lattice Energy: Ion Size and Charge
Total Voids in Concrete
Total Internal Reflection Fluorescence Microscopy

