Related Experiment Video
Updated: Jan 28, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
Simulating Fiber-Reinforced Concrete Mechanical Performance Using CT-Based Fiber Orientation Data
Vladimir Buljak1, Tyler Oesch2, Giovanni Bruno3,4
1Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11120 Belgrade 35, Serbia. vladimir.buljak@polimi.it.
Abstract:
The main hindrance to realistic models of fiber-reinforced concrete (FRC) is the local materials property variation, which does not yet reliably allow simulations at the structural level. The idea presented in this paper makes use of an existing constitutive model, but resolves the problem of localized material variation through X-ray computed tomography (CT)-based pre-processing. First, a three-point bending test of a notched beam is considered, where pre-test fiber orientations are measured using CT. A numerical model is then built with the zone subjected to progressive damage, modeled using an orthotropic damage model. To each of the finite elements within this zone, a local coordinate system is assigned, with its longitudinal direction defined by local fiber orientations. Second, the parameters of the constitutive damage model are determined through inverse analysis using load-displacement data obtained from the test. These parameters are considered to clearly explain the material behavior for any arbitrary external action and fiber orientation, for the same geometrical properties and volumetric ratio of fibers. Third, the effectiveness of the resulting model is demonstrated using a second, "control" experiment. The results of the "control" experiment analyzed in this research compare well with the model results. The ultimate strength was predicted with an error of about 6%, while the work-of-load was predicted within 4%. It demonstrates the potential of this method for accurately predicting the mechanical performance of FRC components.
Related Concept Videos
Fiber Reinforced Concrete
Reinforcements in Concrete
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...
Design Example: Distributing Reinforcements in Concrete Sections
Types of Skeletal Muscle Fibers
Fast-twitch fibers
Fast-twitch fibers, or Type II fibers, are designed for quick, powerful bursts of speed and strength. They reach peak tension within approximately 0.01 seconds following stimulation. Characterized by a large diameter and densely packed myofibrils, these fibers contain...
Formation of Muscle Fibers from Myoblasts
Muscle progenitor cells (MPCs) are formed from the myotomes. MPCs express genes that encode the transcription factors Pax3 and Pax7. Along with Pax 3/7, other transcription...

