The spectral background problem of portable fiber Raman instruments and a solution for the on-site detection of

Haibo Li1, Yuejiao Gu2, Gan Li1

  • 1Science and Technology on Surface Physics and Chemistry Laboratory, Mianyang 621907, People's Republic of China.

Related Concept Videos

Weak Base Solutions03:21

Weak Base Solutions

Some compounds produce hydroxide ions when dissolved by chemically reacting with water molecules. In all cases, these compounds react only partially and so are classified as weak bases. These types of compounds are also abundant in nature and important commodities in various technologies. For example, global production of the weak base ammonia is typically well over 100 metric tons annually, being widely used as an agricultural fertilizer, a raw material for chemical synthesis of other...
25.1K
Weak Acid Solutions04:02

Weak Acid Solutions

Few compounds act as strong acids. A far greater number of compounds behave as weak acids and only partially react with water, leaving a large majority of dissolved molecules in their original form and generating a relatively small amount of hydronium ions. Weak acids are commonly encountered in nature, being the substances partly responsible for the tangy taste of citrus fruits, the stinging sensation of insect bites, and the unpleasant smells associated with body odor. A familiar example of a...
43.0K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.1K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.3K
Titration of a Weak Acid with a Weak Base01:08

Titration of a Weak Acid with a Weak Base

Weak acids and bases do not undergo dissociation completely, and titrations between these two are rarely studied. When such studies are performed, say, for the titration of a weak acid with a weak base, the titration curve plots the change in pH as a function of the volume of base added. Take the titration of acetic acid with ammonia, for instance. During the titration, these two species form ammonium acetate and water, but the pH change is slow and gradual.
As a result, there is no simple...
4.9K
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
49.2K