Related Experiment Video
Updated: Jan 28, 2026

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Aroma Patterns Characterization of Braised Pork Obtained from a Novel Ingredient by Sensory-Guided Analysis and
Shiqing Song1, Li Fan2, Xiaodong Xu3
1School of perfume and aroma technology, Shanghai Institute of Technology, No.100 Hai Quan Road, Shanghai 201418, China. sshqingg@163.com.
Abstract:
Two types of braised pork were prepared from self-made braised sauce added to Maillard reaction intermediate (MRI) and white granulated sugar, respectively. Descriptive sensory analysis and gas chromatography-mass spectrometry (GC-MS) were conducted to investigate their differences in sensory and aroma compounds. The results showed that the effect of self-made braised sauce in braised pork was comparable to white granulated sugar. One-hundred-and-nine volatile flavor compounds were identified by GC-MS using headspace-solid phase microextraction (HS-SPME) and simultaneous distillation and extraction (SDE). Thirty-six odor active compounds with retention indexes ranging from 935⁻2465 were identified by aroma extract dilution analysis (AEDA). Additionally, their odor activity values (OAV) were calculated. It was found that 17 aroma compounds showed an OAV greater than 1. Among them, pentanal (almond, pungent), nonanal (fat, green), (E, E)-2,4-decadienal (fat, roast), phenylacetaldehyde (hawthorn, honey, sweet), dodecanal (lily, fat, citrus) and linalool (floral, lavender) reached the highest OAV values (>200), indicating a significant contribution to the aroma of two types of braised pork. These results indicated that the self-made braised sauce added with MRI could be used for cooking braised pork with good sensory characteristics.
More Related Videos
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
04:36Author Spotlight: Exploring Tea Aroma Using Solvent-Assisted Flavor Evaporation Technique
Published on: May 26, 2023
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....