Related Experiment Video
Updated: Jan 28, 2026

Electrocardiogram Recordings in Anesthetized Mice using Lead II
Published on: June 20, 2020
Comparison of current Federal Reference Methods for ambient lead measurements adjacent to a secondary lead smelter
Donald Ward1, Thomas Gentile1, Henry Felton1
1a Division of Air Resources, New York State Department of Environmental Conservation , Albany , NY , USA.
Abstract:
The United States Environmental Protection Agency (EPA) reduced their National Ambient Air Quality Standard (NAAQS) for lead (Pb) an order of magnitude to a concentration level of 0.15 micrograms per cubic meter (µg/m3) when the new rule was promulgated in 2008. At that time, the possibility of revising the Pb sampling method from total suspended particulate (TSP) to particulate matter less than or equal to 10 µm in diameter (PM10) was considered due to potential measurement bias of the Pb-TSP monitoring technique. The New York State Department of Environmental Conservation (NYSDEC) has been operating source-orientated colocated TSP and PM10 monitors documenting ambient air lead (Pb) concentrations since 2011 at a site adjacent to a secondary Pb smelter in Wallkill, New York. The colocated Wallkill data show a very strong correlation between the readings recorded by these two sampling techniques. After the range of the variability in the individual Pb-PM10/Pb-TSP ratios was reduced by using a 0.005 µg/m3 concentration cut point, because of the concerns about the measurements at low concentrations, an adjustment factor (AF) of 1.49 was calculated using the remaining data set. This AF can be used to estimate Pb-TSP concentrations from Pb-PM10 readings at this Wallkill source-orientated location. It was stated by the EPA that there is only a limited data set in situations where Pb-TSP and Pb-PM10 are colocated, especially for those sites considered to be source-oriented, so the analyses performed and summarized herein for the Wallkill colocated airborne Pb concentration data add to that limited data set. Implications: These data analyses add to the limited data set in situations where Pb-TSP and Pb-PM10 are colocated to help refine the derivation of a site-specific adjustment factor for estimating TSP Pb concentrations from measured PM10 Pb concentrations. This could assist the EPA in transitioning away from the use of the Pb-TSP monitoring technique, with its indicated measurement bias, for the Pb NAAQS to the use of Pb-PM10 instead. An adjustment factor of 1.49 was calculated that could be used to estimate Pb-TSP concentrations from Pb-PM10 values collected around this source-orientated location.
Related Concept Videos
Phase-lead and Phase-lag Controllers
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Secondary Active Transport
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Inertial Frames of Reference

