Related Experiment Video
Updated: Jan 28, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Belt-Mounted Micro-Gas-Chromatograph Prototype for Determining Personal Exposures to Volatile-Organic-Compound
Junqi Wang1,2, Nicolas Nuñovero3,2, Robert Nidetz4,2
1Department of Chemistry , University of Michigan , Ann Arbor , Michigan 48109 , United States.
Abstract:
We describe a belt-mountable prototype instrument containing a gas chromatographic microsystem (μGC) and demonstrate its capability for near-real-time recognition and quantification of volatile organic compounds (VOCs) in moderately complex mixtures at concentrations encountered in industrial workplace environments. The μGC comprises three discrete, Si/Pyrex microfabricated chips: a dual-adsorbent micropreconcentrator-focuser for VOC capture and injection; a wall-coated microcolumn with thin-metal heaters and temperature sensors for temperature-programmed separations; and an array of four microchemiresistors with thiolate-monolayer-protected-Au-nanoparticle interface films for detection and recognition-discrimination. The battery-powered μGC prototype (20 × 15 × 9 cm, ∼2.1 kg sans battery) has on-board microcontrollers and can autonomously analyze the components of a given VOC mixture several times per hour. Calibration curves bracketing the Threshold Limit Value (TLV) of each VOC yielded detection limits of 16-600 parts-per-billion for air samples of 5-10 mL, well below respective TLVs. A 2:1 injection split improved the resolution of early eluting compounds by up to 63%. Responses and response patterns were stable for 5 days. Use of retention-time windows facilitated the chemometric recognition and discrimination of the components of a 21-VOC mixture sampled and analyzed in 3.5 min. Results from a "mock" field test, in which personal exposures to time-varying concentrations of a mixture of five VOCs were measured autonomously, agreed closely with those from a reference GC. Thus, reliable, near-real-time determinations of worker exposures to multiple VOCs with this wearable μGC prototype appear feasible.
Related Concept Videos
Organic Compounds
Mixtures of Acids
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
Volatilization
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Frictional Forces on Flat Belts
Kinetic Molecular Theory and Gas Laws Explain Properties of Gas Molecules

