A comparative study based on deformable image registration of the target volumes for external-beam partial breast
Ting Yu1,2, Jian Bin Li3, Wei Wang2
1School of Medicine and Life Sciences, University of Jinan-Shandong Academy of Medical Sciences, Jinan, Shandong province, China.
Background:
To explore the differences and correlations between the target volumes defined using preoperative prone diagnostic magnetic resonance imaging (MRI) and postoperative prone computed tomography (CT) simulation imaging based on deformable image registration (DIR) for external-beam partial breast irradiation (EB-PBI) after breast-conserving surgery (BCS).
Methods:
Eighteen breast cancer patients suitable for EB-PBI were enrolled. Preoperative prone diagnostic MRI and postoperative prone CT scan sets for all the patients were acquired during free breathing. Target volumes and ipsilateral breast were all contoured by the same radiation oncologist. The gross tumor volume (GTV) delineated on the preoperative MRI images was denoted as the GTVpreMR and the tumor bed (TB) delineated on the postoperative prone CT images was denoted as the GTVpostCT. The MIM software system was used to deformably register the MRI and CT images.
Results:
When based on the coincidence of the compared target centers, there were statistically significant increases in the conformity index (CI) and degree of inclusion (DI) values for GTVpostCT-GTVpreMR, GTVpostCT-CTVpreMR + 10, CTVpostCT + 10-GTVpreMR, and CTVpostCT + 10-CTVpreMR + 10 when compared with those based on the DIR of the thorax (Z = - 3.724, - 3.724, - 2.591, - 3.593, all P < 0.05; Z = -3.724, - 3.724, - 3.201, - 3.724, all P < 0.05, respectively).
Conclusions:
Although based on DIR, there was relatively poor spatial overlap between the preoperative prone diagnostic MRI images and the postoperative prone CT simulation images for either the whole breast or the target volumes. Therefore, it is unreasonable to use preoperative prone diagnostic MRI images to guide postoperative target delineation for EB-PBI.
More Related Videos
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
03:58Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies VII: Vascular Imaging
Deformation of a Beam under Transverse Loading
The insights from the bending moment diagram extend to...