Related Experiment Video
Updated: Jan 28, 2026

Enhancement of the Initial Growth Rate of Agricultural Plants by Using Static Magnetic Fields
Published on: July 8, 2016
Hemiepiphysiodesis using tension band plates: does the initial screw angle influence the rate of correction?
H H Eltayeby1,2, C A Iobst3, J E Herzenberg1
1International Center for Limb Lengthening, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland, USA.
Purpose:
When using tension band plates for angular deformity correction, the literature is unclear regarding the most effective screw insertion angle to use. This study evaluates the correlation between initial screw angle and the average rate of correction during hemiepiphysiodesis using tension band plates.
Methods:
This retrospective study includes 35 patients (47 physes) with genu valgum deformity (17 idiopathic and 18 fibular hemimelia) who underwent insertion of Eight-Plates between 2010 and 2015. Initial screw angle was determined from the intraoperative fluoroscopic images. Radiographs were obtained within three months of surgery, and follow-up films were obtained every three to six months. Change in mechanical lateral distal femoral angle, medial proximal tibial angle and screw angle was obtained from each follow-up radiograph. Initial screw angle was correlated with the average rate of correction during the entire treatment period. The average rate of angular correction during first and last follow-up periods was also compared.
Results:
The relationship between the initial screw angle and the mean rate of angular correction was not statistically significant (p = 0.2). The rate of angular correction during the first follow-up period (mean of 4.7 months) was 0.86° per month compared with 0.71° per month during the last follow-up period (mean of 5.1 months).
Conclusion:
Application of a tension band plate with a divergence angle ranging from 0° to 30° results in similar rates of angular correction. For surgeons inserting screw-plate tension band devices, there does not seem to be any necessity to make the screws parallel or divergent. We recommend that screw placement be anatomically correct, i.e. not impinging on the physis, rather than favouring any particular divergence angle.
Level Of Evidence:
IV.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Factors Influencing the Rate of Chemical Reactions
Concentration and Pressure:
The more particles present within a given space, the more likely those particles are to bump into one another....
Band Theory
The energy difference between these bands is known as the band gap.
Conductor, Semiconductor,...
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Tension
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.

