Related Experiment Video
Updated: Jan 28, 2026

Comparison of Three Different Methods for Determining Cell Proliferation in Breast Cancer Cell Lines
Published on: September 3, 2016
Comparison of GC-MS and MEKC methods for caffeine determination in preworkout supplements
Emilia Waraksa1,2, Andrzej Pokrywka3, Marek Konop4
1Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, Gdańsk, Poland.
Abstract:
In this study, GC-MS- and MEKC-based methods for determination of caffeine (CAF) in preworkout supplements were developed and validated. The proposed protocols utilized minimal sample preparation (simple dilution and syringe filtration). The developed methods achieved satisfactory validation parameters, i.e. good linearity (R2 > 0.9988 and R2 > 0.9985 for GC-MS- and MEKC-based method, respectively), satisfactory intra- and interaccuracy (within 92.6-100.7% for method utilizing GC-MS and 92.1-110.3% for protocol based on MEKC) and precision (CV < 15.9% and CV < 6.3% for GC-MS- and MEKC-based method, respectively) and recovery (within 100.1-100.8% for method utilizing GC-MS and 101.5-106.2% for protocol based on MEKC). The LOD was 0.03 and 3 μg/mL for method utilizing GC-MS and MEKC, respectively. The CAF concentrations determined by GC-MS- and MEKC-based methods were found to be in the range of 8.53-11.23 and 8.20-11.61 μg/mL, respectively. Taking into consideration information on the labels, the investigated supplements were found to contain from 110.0 to 167.3% of the declared CAF content, which confirmed the literature reports on incompatibility of the declared product compositions with real ones. Nevertheless, the consumption of examined supplements as recommended by producers did not lead to exceeding the CAF safe limit of 400 mg per day. Additionally, the MEKC-based method allowed for detection and identification of vitamin B3 and B6 in all of the investigated supplement samples, which demonstrated that MEKC-based protocols may be an appropriate assays for simultaneous determination of CAF and vitamins.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Dose Size and Dosing Frequency: Determination Methods

