Related Experiment Video
Updated: Jan 28, 2026

Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
In vitro test-retest repeatability of invasive physiological indices to assess coronary flow
Fabien Picard1,2, Omar Alansari1, Satoshi Mogi1
1Department of Cardiology, Hôpital Cochin, AP-HP, Paris, France.
Aims:
Several invasive techniques are available in clinical practice to assess coronary flow. Nevertheless, the test-retest repeatability of these techniques in a controlled setting has not been reported. Therefore, we sought to evaluate fractional flow reserve (FFR), coronary flow reserve (CFR), index of microvascular resistance (IMR), and absolute coronary blood flow (ABF) with absolute microvascular resistance (AMR) test-retest repeatability using a coronary flow simulator.
Methods And Results:
Using a coronary flow simulator (FFR WetLab version 2.0; Abbott Vascular, Santa Clara, CA), we created stenoses ranging from 0% to 70%, with 10% increments. Three different flows were established with their hyperemic phases, and two consecutive measurements were obtained, evaluating the following indices: FFR, CFR, IMR, ABF, and AMR, using a pressure/temperature wire and an infusion catheter. One hundred and thirty-eight pairs of measurements were performed. Test-retest reliability was compared in 48 FFR, 18 CFR, 24 IMR, 24 ABF, and 24 AMR. Test-retest repeatability showed excellent reproducibility for FFR, ABF, and AMR; respectively 0.98 (0.97-0.99), 0.92 (0.81-0.97) and 0.91 (0.79-0.96) (P < 0.0001 for all). However, test-retest repeatability was weaker for IMR and poor for CFR; respectively 0.53 (0.16-0.77) (P = 0.006) and 0.27 (-0.26-0.67) (P = 0.30).
Conclusions:
Using a coronary flow simulator, FFR and ABF with AMR had excellent test-retest reliability. IMR and CFR demonstrated weaker test-retest reliability.
Related Concept Videos
Indicators
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Mechanical Ventilation I: Indication and Settings

