Harmonizing by reducing inter-run variability: performance evaluation of a quality assurance program for antinuclear
Laura Bogaert1,2, Stefanie Van den Bremt1, Sofie Schouwers2
1Department of Laboratory Medicine, OLV Hospital Aalst, Aalst, Belgium.
Abstract:
Background The introduction of automated anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) analysis may allow for more harmonized ANA IIF reporting, provided that a thorough quality assurance program controls this process. The aim of this study was to evaluate various quality indicators used for ANA IIF analysis with the final goal of optimizing the iQC program. Methods In an experimental setup, we introduced artificial errors, mimicking plausible problems during routine practice on a QUANTA-Lyser-NOVA View® system (Inova Diagnostics, San Diego, CA, USA). Predetermined quality indicators were evaluated against predefined acceptance criteria. In addition, we retrospectively investigated the applicability of the selected quality indicators in the daily routine practice during three pre-defined periods. Results Both the experimental as the retrospective study revealed that pre-analytical, analytical and post-analytical errors were not highlighted by company internal quality control (iQC) materials. The use of patient derived iQC samples, median fluorescence intensity results per run and the percentage of positive ANA IIF results as additional quality indicators ensured a more adequate ANA IIF quality assurance. Furthermore, negative and moderate positive sample iQC materials merit clinical validation, as titer changes of >1 correspond to clinically important shifts. Traditional Westgard rules, including a clinically defined stop limit, revealed to be useful in monitoring of the supplemental quality indicators. Conclusions A thorough ANA IIF quality assurance for daily routine practice necessitates the addition of supplemental quality indicators in combination with well-defined acceptance criteria.
Related Concept Videos
Quality Assurance
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Indirect Motor Pathways
The vestibulospinal tract originates in the vestibular nuclei of the brainstem. The vestibular system detects changes in...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Energy in Simple Harmonic Motion
Simple Harmonic Motion