Multisection computed tomography: Results from a Chinese survey on radiation dose metrics
Dan-Dan Zhou1, Pengfei Sun1, Zhifang Jia2
1Department of Radiology, The First Hospital of Jilin University, Changchun, China.
Background:
As multisection spiral computed tomography (MSCT) have been extensively used, it is important to consider the amounts of doses the patients are exposed during a computed tomography (CT) examination. The aim of the current study was to summarize MSCT doses in Chinese patients to establish the diagnostic reference levels (DRLs).
Methods:
Radiation dose metrics were retrospectively collected from 164,073 CT examinations via the Radimetrics Enterprise Platform. Radiation dose metrics (volume CT dose index [CTDIvol], dose-length product [DLP], effective dose [ED], and organ dose) and size-specific dose estimate (SSDE) were calculated for adults and children based on anatomic area and scanner type.
Results:
The median CTDIvol and DLP values were highest in the head at 51.7 mGy (interquartile range [IQR], 33.2-51.7 mGy) and 906.5 mGy·cm (IQR, 582.4-1068.2 mGy·cm) and lowest in the chest at 7.9 mGy (IQR, 7.9-10.3 mGy) and 284.8 mGy·cm (IQR, 249.0-412.6 mGy·cm), respectively. The median SSDE values of chest and pelvis were 12.1 mGy (IQR, 10.8-14.1 mGy) and 36.3 mGy (IQR, 34.0-38.9 mGy), respectively. EDs for children were similar to adults except for an increased 1.5-, 0.77-, and 1.7-fold in the chest, neck, and pelvis, respectively (p < 0.001). Furthermore, radiation doses tended to increase with increasing slice number and decrease when exposure reduction techniques were used.
Conclusion:
Our findings provide a basis for the evaluation of CT radiation doses and evidence for establishment of DRLs in China.