Related Experiment Video
Updated: Jan 28, 2026

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Multimodality imaging for real-time image-guided left ventricular lead placement during cardiac resynchronization
Odette A E Salden1, Hans T van den Broek2, Wouter M van Everdingen2
1Department of Cardiology, University Medical Center Utrecht, Heidelberglaan 100, P.O. Box 85500, 3584 CX, Utrecht, The Netherlands. o.a.e.salden@umcutrecht.nl.
Abstract:
This study was performed to evaluate the feasibility of intra-procedural visualization of optimal pacing sites and image-guided left ventricular (LV) lead placement in cardiac resynchronization therapy (CRT). In fifteen patients (10 males, 68 ± 11 years, 7 with ischemic cardiomyopathy and ejection fraction of 26 ± 5%), optimal pacing sites were identified pre-procedurally using cardiac imaging. Cardiac magnetic resonance (CMR) derived scar and dyssynchrony maps were created for all patients. In six patients the anatomy of the left phrenic nerve (LPN) and coronary sinus ostium was assessed via a computed tomography (CT) scan. By overlaying the CMR and CT dataset onto live fluoroscopy, aforementioned structures were visualized during LV lead implantation. In the first nine patients, the platform was tested, yet, no real-time image-guidance was implemented. In the last six patients real-time image-guided LV lead placement was successfully executed. CRT implant and fluoroscopy times were similar to previous procedures and all leads were placed close to the target area but away from scarred myocardium and the LPN. Patients that received real-time image-guided LV lead implantation were paced closer to the target area compared to patients that did not receive real-time image-guidance (8 mm [IQR 0-22] vs 26 mm [IQR 17-46], p = 0.04), and displayed marked LV reverse remodeling at 6 months follow up with a mean LVESV change of -30 ± 10% and a mean LVEF improvement of 15 ± 5%. Real-time image-guided LV lead implantation is feasible and may prove useful for achieving the optimal LV lead position.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Imaging Studies VII: Vascular Imaging
Imaging Studies IV: Magnetic Resonance Imaging
X-ray Imaging