Related Experiment Video
Updated: Jan 28, 2026

Measurements of CO2 Fluxes at Non-Ideal Eddy Covariance Sites
Published on: June 24, 2019
Accounting for spectroscopic effects in laser-based open-path eddy covariance flux measurements
George Burba1,2, Tyler Anderson3, Anatoly Komissarov1
1R&D, LI-COR Biosciences, Lincoln, Nebraska.
Abstract:
A significant portion of the production and consumption of trace gases (e.g. CO2 , CH4 , N2 O, NH3 , etc.) by world ecosystems occurs in areas without sufficient infrastructure or easily available grid power to run traditional closed-path flux stations. Open-path analyzer design allows such measurements with power consumption 10-150 times below present closed-path technologies, helping to considerably expand the global coverage and improve the estimates of gas emissions and budgets, informing the remote sensing and modeling communities and policy decisions, all the way to IPCC reports. Broad-band nondispersive infrared devices have been used for open-path CO2 and H2 O measurements since the late 1970s, but since recently, a growing number of new narrow-band laser-based instruments are being rapidly developed. The new design comes with its own challenges, specifically: (a) mirror contamination, and (b) uncontrolled air temperature, pressure and humidity, affecting both the gas density and the laser spectroscopy of the measurements. While the contamination can be addressed via automated cleaning, and density effects can be addressed via the Webb-Pearman-Leuning approach, the spectroscopic effects of the in situ temperature, pressure and humidity fluctuations on laser-measured densities remain a standing methodological question. Here we propose a concept accounting for such effects in the same manner as Webb et al. proposed to account for respective density effects. Derivations are provided for a general case of flux of any gas, examined using a specific example of CH4 fluxes from a commercially available analyzer, and then tested using "zero-flux" experiment. The proposed approach helps reduce errors in open-path, enclosed, and temperature- or pressure-uncontrolled closed-path laser-based flux measurements due to the spectroscopic effects from few percents to multiple folds, leading to methodological advancement and geographical expansion of the use of such systems providing reliable and consistent results for process-level studies, remote sensing and Earth modeling applications, and GHG policy decision-making.
More Related Videos
Related Concept Videos
Eddy Currents
Other major applications of eddy currents appear in metal detectors and the braking systems of trains and roller...
Path Between Thermodynamics States
Mean free path and Mean free time
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion
Theory of Attribution II: Kelley's Covariation Theory

