Related Experiment Video
Updated: Jan 28, 2026

Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
A Deep Learning System for Automated Angle-Closure Detection in Anterior Segment Optical Coherence Tomography Images
Huazhu Fu1, Mani Baskaran2, Yanwu Xu3
1Cixi Institute of Biomedical Engineering, Ningbo Institute of Industrial Technology, Chinese Academy of Sciences, Zhejiang, China; Inception Institute of Artificial Intelligence, Abu Dhabi, United Arab Emirates; Institute for Infocomm Research, Agency for Science, Technology and Research, Singapore.
Purpose:
Anterior segment optical coherence tomography (AS-OCT) provides an objective imaging modality for visually identifying anterior segment structures. An automated detection system could assist ophthalmologists in interpreting AS-OCT images for the presence of angle closure.
Design:
Development of an artificial intelligence automated detection system for the presence of angle closure.
Methods:
A deep learning system for automated angle-closure detection in AS-OCT images was developed, and this was compared with another automated angle-closure detection system based on quantitative features. A total of 4135 Visante AS-OCT images from 2113 subjects (8270 anterior chamber angle images with 7375 open-angle and 895 angle-closure) were examined. The deep learning angle-closure detection system for a 2-class classification problem was tested by 5-fold cross-validation. The deep learning system and the automated angle-closure detection system based on quantitative features were evaluated against clinicians' grading of AS-OCT images as the reference standard.
Results:
The area under the receiver operating characteristic curve of the system using quantitative features was 0.90 (95% confidence interval [CI] 0.891-0.914) with a sensitivity of 0.79 ± 0.037 and a specificity of 0.87 ± 0.009, while the area under the receiver operating characteristic curve of the deep learning system was 0.96 (95% CI 0.953-0.968) with a sensitivity of 0.90 ± 0.02 and a specificity of 0.92 ± 0.008, against clinicians' grading of AS-OCT images as the reference standard.
Conclusions:
The results demonstrate the potential of the deep learning system for angle-closure detection in AS-OCT images.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Imaging Studies III: Computed Tomography
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle of Twist: Problem Solving

