Related Experiment Video
Updated: Jan 28, 2026

Synthesis and Exfoliation of Discotic Zirconium Phosphates to Obtain Colloidal Liquid Crystals
Published on: May 25, 2016
Development of a portable setup using a miniaturized and high precision colorimeter for the estimation of phosphate
Jun-Chao Yan1, Jun Ren2, Lin-Lin Ren2
1Institute of Microelectronics, Tsinghua University, Beijing, 100084, China; Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing, 100084, China; Graduate School at Shenzhen, Tsinghua University, Shenzhen, 518055, China; Department of Electronic Engineering, Tsinghua University, Beijing, 100084, China.
Abstract:
In this work, a high integrated water detection system comprised a miniaturized and high precision homemade colorimeter, a microfluidic analysis module and a wireless module was reported. A reagent reaction based on the ammonium molybdate spectrophotometric method was recorded for the estimation of phosphate in natural water. A laser self-modulating module of 880 nm was used as the radiation source. A microfluidic chip was employed to fit the colorimeter with an optimized micro flow path for low liquid consumption and high precision detection. The wireless module consisted of two parts, using ZigBee and GSM modules to realize short and remote displaying and controlling. Applying a novel optimized algorithm, a wide linear response was obtained ranging from 0.02 up to 9.5 mg L-1. The optimization of colorimeterare mainly in the core detection part, allowing an improvement of the detection limit, achieving a result of 0.009 mg L-1. A low reagent consumption of 0.004 mg ascorbic acid and 0.011 mg ammonium molybdate for per determination was attained. Experimental results have also shown that the system could maintain good stability among broad room temperature changing from 17 °C to 35 °C with less energy consumption. The miniaturized colorimeter-based water detection system opens new avenue for operating in remote distance to get high precision measurements of phosphate in natural water.
Related Concept Videos
Phosphate Buffer
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...
Nature and Nurture
What is Natural Selection?
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Uncertainty in Measurement: Accuracy and Precision
Roles of Electrolytes: Calcium and Phosphate
The calcium concentration in blood plasma is primarily...

