Selecting the best piping arrangement for scaling-up an annular channel reactor: An experimental and computational

Francisca C Moreira1, Elvira Bocos2, Ana G F Faria1

  • 1Laboratory of Separation and Reaction Engineering - Laboratory of Catalysis and Materials (LSRE-LCM), Departamento de Engenharia Química, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal.

Related Concept Videos

The Role of Ion Channels in Neuronal Computation01:19

The Role of Ion Channels in Neuronal Computation

A postsynaptic neuron usually receives numerous impulses from several other presynaptic neurons. The axon hillock of the postsynaptic neuron integrates all these signals and determines the likelihood of firing an action potential.
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
3.8K
Fascicle Arrangement in Skeletal Muscles01:25

Fascicle Arrangement in Skeletal Muscles

Fascicles are bundles of muscle fibers in a skeletal muscle. Muscle fascicle arrangement is directly associated with the power and range of motion of various muscles. The configuration of these fascicles can vary, leading to different functional outcomes.
The four primary types of muscle based on fascicle arrangement are:
3.9K
General Characteristics of Pipe Flow I01:22

General Characteristics of Pipe Flow I

Pipe flow refers to the movement of fluids within fully enclosed conduits, typically cylindrical in shape, such as water pipes or hydraulic hoses. These conduits are designed to withstand high-pressure gradients that drive fluid movement, contrasting with open-channel flows, where gravity is the primary driving force. Rectangular conduits, like air conditioning and heating ducts, generally operate at lower pressures and are less suited for high-pressure applications.
The classification of fluid...
1.7K
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K
Minor Losses in Pipes01:25

Minor Losses in Pipes

In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.9K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
351