Related Experiment Video
Updated: Jan 28, 2026

A Simple Double Centrifugation Tube Method to Obtain Platelet-rich Plasma from Equine Blood
Published on: August 15, 2025
Fast and Simple LC-MS/MS Method for Rifampicin Quantification in Human Plasma
Žane Temova Rakuša1, Robert Roškar1, Anita Klančar Andrejc1
1University of Ljubljana, Faculty of Pharmacy, Ljubljana, Slovenia.
Abstract:
A simple, fast, and cost-effective LC-MS/MS method for quantification of rifampicin in human plasma was developed and fully validated. The plasma samples containing rifampicin and isotopically labelled internal standard rifampicin D8, were cleaned up using a Captiva ND Lipids filtration plate. Chromatographic separation was achieved on an 1290 Infinity liquid chromatograph coupled to 6460 Triple Quadrupole operated in positive mode on a core-shell Kinetex C18 column (50 × 2.1 mm, 2.6 μm) by gradient elution using 0.1% formic acid in water and acetonitrile as a mobile phase. The proposed method is the fastest method published by now, both in terms of sample preparation (approximately one minute per sample) and chromatographic analysis (total run time 2.4 min). Another key benefit is the outstanding sensitivity and wide analytical range (5-40000 μg/L) with good linearity, accuracy, and precision. The method showed almost complete recovery (92%) and absence of any significant matrix effect as demonstrated by uniform responses from QC samples prepared in blood plasma from 6 volunteers (RSD <5%). The proposed method was successfully applied to rifampicin quantification in 340 patients' plasma samples, thus demonstrating its suitability for both therapeutic drug monitoring and pharmacokinetic analysis.
More Related Videos
10:01Quantification of Intracellular Growth Inside Macrophages is a Fast and Reliable Method for Assessing the Virulence of Leishmania Parasites
Published on: March 16, 2018
07:14Detection and Quantification of Calcitonin Gene-Related Peptide CGRP in Human Plasma Using a Modified Enzyme-Linked Immunosorbent Assay
Published on: June 16, 2023
Related Concept Videos
Fast Fourier Transform
The computational efficiency of the FFT becomes...
Composition of Blood Plasma
Gene Evolution - Fast or Slow?
In contrast, regions which code...
Gene Evolution - Fast or Slow?
Fast Decoupled and DC Powerflow
Simple Pendulum
The period of a simple pendulum depends on two factors: its length and the acceleration due to gravity. The period is completely independent of any other factors, such as mass or maximum displacement. For small displacements, a pendulum is...