Safety and efficacy of computed tomography-guided dye localization using patent blue V for single lung nodule for
Jing-Ru Chen1, Yao-Hui Tseng2, Mong-Wei Lin3
1Department of Medical Imaging, National Taiwan University Hospital and National Taiwan University College of Medicine, Taichung, Taiwan.
Background:
For invisible or impalpable lung nodules, video-assisted thoracoscopic surgery (VATS) has some limitations; some preoperative localization has been developed to overcome this limitation. This study aimed to assess the safety and efficacy of preoperative computed tomography (CT)-guided localization with patent blue V dye.
Methods:
In this retrospective study, we examined patients with solitary pulmonary nodule undergoing preoperative CT-guided patent blue V dye localization from 2013 to 2015. We analyzed patients' demographic data, nodular features, and procedures undergone.
Results:
We enrolled 282 patients (282 lung nodules; mean age: 56.6±11.6 years, with female preponderance) in this study. The mean size of nodules was 0.9±0.5 cm, and mean time of localization was 24 min. The leading complications after localization were asymptomatic pneumothorax (48 patients, 17%) and localized pulmonary hemorrhage (51 patients, 18%). Other rare complications included subcutaneous emphysema and hematoma. We noted two cases with intraoperative poor or fail dye localization. Most patients underwent wedge resection (221 patients, 78.4%) and segmentectomy (36 patients, 12.8%), whereas 25 patients underwent lobectomy (8.9%) after the intraoperative frozen histopathological study confirmed malignancy. Furthermore, postoperative hospital stay was 4.8±2.0 days. Few patients experienced postoperative complications such as empyema (n=1), air leakage (n=3), and chylothorax (n=1).
Conclusions:
This study establishes that CT-guided dye localization is a safe and efficient method with rare severe complications and high success rate.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Survey Safety
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Lung Capacity
Self-Efficacy