Related Experiment Video
Updated: Jan 28, 2026

Noninvasive and Invasive Renal Hypoxia Monitoring in a Porcine Model of Hemorrhagic Shock
Published on: October 28, 2022
Oxygen-reducing microbial cathodes monitoring toxic shocks in tap water
Antonin Prévoteau1, Peter Clauwaert1, Frederiek-Maarten Kerckhof1
1Center for Microbial Ecology and Technology (CMET), Campus Coupure - Ghent University, Coupure Links 653, 9000 Ghent, Belgium.
Abstract:
Electroactive biofilms (EABs) have recently attracted considerable research interest for their possible use as amperometric biosensors in environmental or bioprocess monitoring, for example for in situ detection of toxic compounds. Almost exclusively, corresponding research has focused on heterotrophic, anodic EABs. These biofilms require sufficiently high organic loads and anoxic conditions to deliver a stable baseline current. Conversely, electroautotrophic O2-reducing EABs have recently been proposed to monitor toxic shocks in oxic solutions that are poor or devoid of organic substrate. This was done in optimal media and only assessed for formaldehyde as a model toxic compound. Here we show that O2-reducing EABs can grow in unamended tap water on carbon electrodes at + 0.2 V vs. Ag/AgCl. They retained substantial electroactivity for at least eight months without adding exogenous compounds. The most represented operational taxonomic units were assigned to the phylum Gammaproteobacteria (25 ± 15%, n = 5 electrodes). Cyclic voltammograms showed a reproducible nernstian behavior for O2 reduction with a mid-wave potential at + 0.27 V and variable plateau current densities ranging from - 1 to - 22 µA cm-2 (n = 10 electrodes). The biocatalytic current was substantially impacted by the addition of either of three tested heavy metals (Hg(II), Cr(VI) or Pb(II)) or by organic pollutants (formaldehyde, 2,4-dichlorophenol, benzalkonium chloride), with limits of detection ranging from 0.5 to 10 mg L-1 (2.5-61 µmol L-1). Response times were typically around 1 min. Comparison with previous reports suggests that O2-reducing microbial cathodes may be more sensitive to toxic shocks than anodic, heterotrophic EABs.
More Related Videos
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Related Concept Videos
Adaptations that Reduce Water Loss
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Water and Mineral Acquisition
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Microbial Morphologies