Related Experiment Video
Updated: Jan 27, 2026

Evaluation of a Smartphone-based Human Activity Recognition System in a Daily Living Environment
Published on: December 11, 2015
In situ evaluation of a persistent disinfectant provides continuous decontamination within the clinical environment
Michael G Schmidt1, Sarah E Fairey1, Hubert H Attaway1
1Department of Microbiology and Immunology, Medical University of South Carolina, Charleston, SC.
Abstract:
Microbial bioburden associated with the built environment can impact the rate of health care-associated infection acquisition; higher bioburden results in a greater incidence of health care-associated infections. Two disinfectants registered by the US Environmental Protection Agency and a trial disinfectant were evaluated for their ability to limit the establishment of bioburden subsequent to application under in situ conditions on patient bed rails within a medical intensive care unit. Bioburden samples were collected immediately prior to disinfection and at 1, 6, and 24 hours after application. The trial disinfectant was engineered to provide continuous disinfection over a 24-hour period. Each disinfectant was able to significantly control bioburden for the first hour. In comparison, the persistent agent was found superior for all time points when compared to a dilutable quaternary ammonium agent, and it was significantly better for controlling bioburden for 2 of the 3 times points for the disinfectant with ethanol and quaternary ammonium as its agent.
More Related Videos
13:22Detection of the Genome and Transcripts of a Persistent DNA Virus in Neuronal Tissues by Fluorescent In situ Hybridization Combined with Immunostaining
Published on: January 23, 2014
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Continuing Care
Continuity Equation
The mass flow rate is expressed as:
Continuity Equation