Related Experiment Video
Updated: Nov 21, 2025

Cryosectioning and Immunostaining Mouse Inner Ear Tissue: From Embryonic to Adult Stages
Published on: April 11, 2025
Blood Pressure Variability Is Associated with Hearing and Hearing Loss: A Population-Based Study in Males
Minghui Bao1, Yongjian Song2,3, Jun Cai4
1Department of Heart Center, Chaoyang Hospital, Capital Medical University, Beijing, China.
Abstract:
Blood pressure (BP) has been well documented to be associated with hearing loss previously. However, the role of blood pressure variability (BPV, representing BP fluctuation over a time period) on hearing remains unknown. We aimed to evaluate the relationship between BPV and hearing in Chinese population. We included 8646 male subjects from a population-based study (the Kailuan study). BP was measured every two years at routine physical examinations from 2006 to 2015. Based on five annual BP measurements, BPV was estimated by standard deviation of BP (SD), coefficient of the variation of BP (CV), and variation independent of mean of BP (VIM). Hearing was estimated by pure-tone average threshold (PTA) at low, intermediate, and high frequencies in the year of 2014. Regression models were used to evaluate the relationship between BPV and hearing. The results showed that PTAs and percentages of hearing loss at low, intermediate, and high frequencies grew gradually with increasing systolic SD (SSD) (p<0.05). After adjusting for multiple covariates, multivariate regression analyses demonstrated that variations of SBP (SSD, SCV, and VIMSBP) were all positively correlated with PTA at intermediate and high frequencies (p<0.05). Each SD increase in SSD, SCV, and VIMSBP was also positively associated with hearing loss at intermediate and high frequencies. No significant correlation was observed between variations of DBP and hearing. These findings suggest that increase in long-term BPV is associated with hearing and hearing loss. Trial registration number: Kailuan study (ChiCTRTNC-11001489).
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Factors affecting Blood pressure
Physiological Factors:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

