Related Experiment Video
Updated: Jan 27, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Efficacy of Low-Dose Compared With Standard-Dose Radiation for Cardiac Catheterization and Intervention (KAR RAD
Subrata Kar1, Mohamed Teleb, Aymen Albaghdadi
1Texas Tech University Health Sciences Center El Paso, Paul L. Foster School of Medicine, 4800 Alberta Avenue, El Paso, TX 79905 USA. skar762@aim.com.
Objectives:
We evaluated the efficacy of low-dose (LD) radiation (≤7.5 frames/second [f/s]) compared with standard-dose (SD) radiation (≥10 f/s) in cardiac catheterization (CC) and percutaneous coronary intervention (PCI). Patients undergoing CC with LD vs SD radiation have not been previously studied.
Methods:
We performed an observational study of 452 consecutive patients (61 ± 12 years) who had coronary angiography or PCI from September 2016 to September 2017. Patients were divided into an LD radiation group (n = 136) consisting of 0.5 f/s and 1 f/s (n = 73), 4 f/s (n = 40), or 7.5 f/s fluoroscopy (n = 23) with 7.5 f/s cine angiography vs an SD group (n = 316) consisting of 10 f/s (n = 250), 15 f/s (n = 64), or 30 f/s fluoroscopy (n = 2) and 10-30 f/s cine angiography. Primary endpoints included air kerma, dose area product (DAP), fluoroscopy time, and contrast use.
Results:
Compared with SD radiation, LD radiation was associated with a significant reduction in air kerma (100.70 mGy [IQR, 46.42-233.35 mGy] vs 660.96 mGy [IQR, 362.78-1373.65 mGy]; P<.001), DAP (723.60 microGy•m² [IQR, 313.09-2328.22 microGy•m²] vs 5203.40 microGy•m² [IQR, 2743.55-10064.71 microGy•m²]; P<.001), and contrast use (100 mL [IQR, 60-150 mL] vs 115 mL [IQR, 80-180 mL]; P<.03). No difference in fluoroscopy time was noted (13.33 min [IQR, 6.93-25.55 min] vs 12.75 min [IQR, 7.75-22.55 min]; P=.95).
Conclusions:
LD radiation in CC was efficacious, with significant radiation reduction and without an increase in fluoroscopy time or contrast utilization. All patients underwent successful LD radiation catheterization without conversion to SD.
Related Concept Videos
Dose-Response Relationship: Potency and Efficacy
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Cardiac Catheterization II: Right Heart Catheterization
Bioavailability Study Design: Single Versus Multiple Dose Studies