Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
Insertion of a preloaded Monoka™ stent for congenital nasolacrimal obstruction: Intraoperative observations. A
B Fayet1, E Racy2, J Katowitz3
1Department of ophthalmology, Hospital Cochin, University of Paris Descartes - Medical School, rue du faubourg Saint-Jacques, Paris, France.
Study Objective:
To study the intraoperative deployment of a pre-loaded probe for a "pushed" monocanalicular nasolacrimal intubation.
Study Design:
Non-randomized study of consecutive cases.
Materials And Methods:
Description: A classical Monoka™ silicone stent with the silicone tube attached at right angles to the punctal plug is contained entirely inside an introducer connected to a piston. Insertion: The procedure begins with intubation of the nasolacrimal duct with the metallic introducer. Traction on the piston retracts the metallic introducer inside the handpiece. This relative shortening progressively ejects the stent, starting with its free end at the bottom of the introducer. The operation was observed endoscopically under single-blind conditions.
Results:
Twenty-eight preloaded Monoka™ stents were placed consecutively, in 28 congenital nasolacrimal duct intubations in 22 patients (28 sides). Endoscopic examination showed that the free part of the stent was progressively ejected from the introducer during retraction of the piston. Insertion of this pushed stent into the nasal cavity was effective in 23/28 cases (82.1%). A total of 28 preloaded stent insertions were attempted and 23 were correctly deployed.
Difficulties Encountered:
At the end of nasolacrimal duct intubation, contact between the punctal plug and the lacrimal punctum was problematic in four cases (4/28=14.2%). At the beginning of stent placement, premature ejection of the punctal plug within the end of the introducer occurred in five cases (5/28=17.8%). These five stents failed to insert properly into the nasal cavity. At the end of insertion, retention of the punctal plug in the introducer occurred in two cases (2/28=7.1%).
Complications:
No cases of intraoperative or postoperative epistaxis were observed.
Conclusions:
Intraoperative nasal endoscopy validated the concept of the preloaded Monoka stent and its deployment. Reproducibility and improved reliability may require a change in stenting technique and a design modification.
More Related Videos
05:19Author Spotlight: An Effective Traditional Chinese Medicinal Treatment for Chronic Obstructive Pulmonary Disease with Abdominal Distension
Published on: September 1, 2023
04:30A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Related Concept Videos
Observational Studies
There are three types of observational studies – Prospective, retrospective, and cross-sectional.
Prospective Study
Prospective studies, also known as longitudinal or cohort studies, are carried out by collecting future data from groups sharing similar characteristics. One...
Naturalistic Observations
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Actor-Observer Effect
Observational Learning
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...