Related Experiment Video
Updated: Jan 27, 2026

Biomechanical Characterization of Human Soft Tissues Using Indentation and Tensile Testing
Published on: December 13, 2016
A Biomechanical Comparison of Six Suture Configurations for Soft Tissue-Based Graft Traction and Fixation
F Alan Barber1, Michael S Howard1, Justin Piccirillo2
1Plano Orthopedic Sports Medicine Center, Plano, Texas, U.S.A.
Purpose:
The purpose of this study was to compare 6 different graft fixation techniques to determine the preparation speed, fixation security, biomechanical strength, and resultant tissue trauma.
Methods:
Six different techniques (10 samples each): #2 OrthoCord Krackow stitch, #2 FiberWire Krackow stitch, SpeedTrap, WhipKnot, Loop-in-loop stitch were created in the distal 3 cm of 9 cm bovine flexor tendons. The proximal 3 cm tendon segment was clamped in a testing machine and the distal suture ends secured by pneumatic grips. 3 preload cycles (10N-100N) and 50N static load was followed by 500 cycles (50N-200N) and then loaded to failure. Graft preparation times, 100 and 500 cycle displacement, maximum failure load, stiffness, and failure mode were recorded.
Results:
Representative graft preparation times were: OrthoCord Krackow (247s), FiberWire Krackow (401s), FiberLoop (177s), SpeedTrap (42s), WhipKnot (39s), Loop-in-loop (45s). No WhipKnots survived cyclic loading. 100 cycle displacements were: OrthoCord Krackow (11.5 ± 3.9 mm), FiberWire Krackow (8.9 ± 1.2 mm), FiberLoop (14.2 ± 6.1 mm), SpeedTrap (8.8 ± 2.5 mm), Loop-in-loop (10.4 ± 2.9 mm). FiberLoop displaced significantly more than all others (P = .016). Maximum failure loads were: OrthoCord Krackow (364 ± 24N), FiberWire Krackow (375 ± 45N), FiberLoop (413 ± 95N), SpeedTrap (437 ± 65N), WhipKnot (153 ± 42N), Loop-in-loop (329 ± 112N). The most common failure mode was suture breaking. FiberWire containing constructs (Krackow and FiberLoop) shredded or cut through ("cheese wiring") prior to failure in a majority.
Conclusions:
SpeedTrap, WhipKnot and Loop-in-loop were quickest to create (under 1 minute). The Krackow, SpeedTrap, WhipKnot, and Loop-in-Loop did not damage the tendon during cyclic loading. SpeedTrap and Krackow had the least displacement. FiberLoop displaced more than all other groups (P = .016). No WhipKnot completed cyclic loading. The SpeedTrap (437N) and FiberLoop (413N) had the highest ultimate strength.
Clinical Relevance:
While the SpeedTrap and FiberLoop are the strongest techniques, the FiberLoop shreds the tendon, displaced the most, and took longer to create. Based on these results, the SpeedTrap demonstrates the best overall performance.
Related Concept Videos
Electron Configurations
The relative energies of the subshells determine the order in which atomic orbitals are filled (1s, 2s, 2p, 3s, 3p,...
Controller Configurations
Control-system compensation involves various configurations, most commonly series or cascade compensation, in which the controller...
Electron Configuration of Multielectron Atoms
Stability of Equilibrium Configuration
A stable equilibrium occurs when a system tends to return to its original position when given a small displacement, and the potential energy is at its minimum. An example of a stable equilibrium is when a cantilever beam is fixed at one end and a weight is attached to the other end. If the weight...
Configurations of BJT
The common base configuration is noted for its high voltage gain, positioning it as an ideal choice for single-stage amplifier circuits, such as microphone pre-amplifiers. A notable...
The Sense of Self: Reflected Self-Appraisal and Social Comparison

