Related Experiment Video
Updated: Jan 27, 2026

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Limitations of Quantitative Blush Evaluator (QuBE) as myocardial perfusion assessment method on digital coronary
Haryadi Prasetya1,2, Marcel A M Beijk3, Praneeta R Konduri1,1
1Department of Biomedical Engineering Physics, Academic Medical Center, Amsterdam, the Netherlands.
Background And Aim:
Quantitative Blush Evaluator (QuBE) is a software application that allows quantifying myocardial perfusion in coronary angiograms after a percutaneous coronary intervention. QuBE has some limitations such as the application of a crude filter to remove large scale structures and the absence of correction for cardiac motion. This study investigates the extent of these limitations and we hypothesize that enhanced image analysis methods can provide improvements.
Methods:
We calculated QuBE scores of 117 patients from the HEBE Trial and determined its association with the Myocardial Blush Grade (MBG) score. Accuracy of large-structure removal is qualitatively assessed for various sizes of a median filter. The influence of cardiac motion was evaluated by comparing the blush curve and QuBE score of the native QuBE with manually motion-corrected QuBE for 40 patients. The effect of different kernel sizes and motion correction to a potential improvement of the association between QuBE score and MBG was studied.
Results:
In our population, there was no significant association between QuBE score and MBG (p = 0.14). Median filters of various kernel sizes were unable to remove large structure related noise. Variations in filters and cardiac movement correction did not result in an improvement in the association with MBG scores (observer 1: p = 0.66; observer 2: p = 0.72).
Conclusions:
There was no significant association of QuBE with MBG scores in our population, which suggests that QuBE is not suitable for a quantitative assessment of myocardial perfusion. Alternative kernel sizes for the large structure removal filter and cardiac motion correction did not improve QuBE performance.
Relevance For Patients:
Further improvements of QuBE to overcome its inherent limitations are necessary in order to establish QuBE as a reliable myocardial perfusion assessment method.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Limiting Reactant
The Number e as a Limit
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Central Limit Theorem
The sample size, n, that...

