Related Experiment Video
Updated: Jan 27, 2026

08:41
Lensfree On-chip Tomographic Microscopy Employing Multi-angle Illumination and Pixel Super-resolution
Published on: August 16, 2012
12.0K
Nanoscopy on-a-chip: super-resolution imaging on the millimeter scale.
Optics Express
|March 17, 2019
Summary
Chip-based nanoscopy now achieves 75 nm resolution over large areas, overcoming previous limitations. This breakthrough enables high-throughput imaging for disease diagnostics and early cancer detection.
Area of Science:
- Biomedical Optics
- Nanotechnology
- Microscopy
Background:
- Optical nanoscopy bridges resolution gaps between optical and electron microscopy.
- Conventional nanoscopy has limitations in high-throughput data generation due to small imaging regions.
- Existing super-resolution methods offer resolutions of 100 nm or better.
Purpose of the Study:
- To demonstrate chip-based nanoscopy with significantly improved resolution and field-of-view.
- To benchmark the performance of chip-based nanoscopy for diagnostic applications.
- To explore the potential of large field-of-view nanoscopy for disease detection.
Main Methods:
- Development of a photonic chip-based nanoscopy system.
- Utilizing a low magnification, high numerical aperture (N.A.) objective lens.
- Benchmarking performance through analysis of localization precision and illumination homogeneity across varying waveguide widths.
Main Results:
- Achieved a lateral resolution of 75 nm.
- Demonstrated imaging over an exceptionally large area of 0.5 mm × 0.5 mm.
- Validated performance metrics for chip-based nanoscopy.
Conclusions:
- Chip-based nanoscopy now offers high resolution over large fields-of-view.
- This advancement opens new diagnostic possibilities requiring high throughput, such as early cancer detection.
- The technology has the potential to revolutionize the detection of rare events and non-diffuse diseases.
Related Concept Videos
Super-resolution Fluorescence Microscopy
14.5K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.5K
pH Scale
79.4K
Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
79.4K
Scaling
592
In designing and analyzing filters, resonant circuits, or circuit analysis at large, working with standard element values like 1 ohm, 1 henry, or 1 farad can be convenient before scaling these values to more realistic figures. This approach is widely utilized by not employing realistic element values in numerous examples and problems; it simplifies mastering circuit analysis through convenient component values. The complexity of calculations is thereby reduced, with the understanding that...
592
Chromatin Immunoprecipitation- ChIP
12.3K
Chromatin immunoprecipitation, or ChIP, is an antibody-based technique used to identify sites on DNA that bind to transcription factors of interest or histone proteins. It also helps determine the type of histone modifications such as acetylation, phosphorylation, or methylation.
Types of ChIP
ChIP can be divided into two types - X-ChIP and N-ChIP. X-ChIP involves in vivo cross-linking of histones and regulatory proteins to DNA, fragmenting the DNA by sonication, and isolating the protein-DNA...
Types of ChIP
ChIP can be divided into two types - X-ChIP and N-ChIP. X-ChIP involves in vivo cross-linking of histones and regulatory proteins to DNA, fragmenting the DNA by sonication, and isolating the protein-DNA...
12.3K
Thermometers and Temperature Scales
7.5K
Any physical property that depends consistently and reproducibly on temperature can be used as the basis of a thermometer. For example, volume increases with temperature for most substances. This property is the basis for the common alcohol thermometer and the original mercury thermometers. Other properties used to measure temperature include electrical resistance, color, and the emission of infrared radiation.
As many physical properties depend on temperature, the variety of thermometers is...
As many physical properties depend on temperature, the variety of thermometers is...
7.5K
Chromatographic Resolution
2.1K
In chromatography, a solute moves through a chromatographic column and tends to spread, forming a Gaussian-shaped band. The longer the solute spends in the column, the broader the band becomes. The broadening can lead to overlaps within the column, affecting separation effectiveness.
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
2.1K

