Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least

Wen Zhang1, Ran Zhou1, Ping Yang1

  • 1Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology (HUST), Wuhan, Hubei 430074, PR China.

Talanta
|March 17, 2019
PubMed

Related Concept Videos

Radical Substitution: Allylic Chlorination01:31

Radical Substitution: Allylic Chlorination

Typically, when alkenes react with halogens at low temperatures, an addition reaction occurs. However, upon increasing the temperature or under reaction conditions that form radicals, providing a low but steady concentration of halogen radicals, allylic substitution reaction is favored. This is because allylic hydrogens are very reactive as the formed intermediate is resonance stabilized. For example, when propene is treated with chlorine in the gas phase at 400 °C, it undergoes allylic...
3.2K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
1.7K
Regression Toward the Mean01:52

Regression Toward the Mean

Regression toward the mean (“RTM”) is a phenomenon in which extremely high or low values—for example, and individual’s blood pressure at a particular moment—appear closer to a group’s average upon remeasuring. Although this statistical peculiarity is the result of random error and chance, it has been problematic across various medical, scientific, financial and psychological applications. In particular, RTM, if not taken into account, can interfere when...
6.9K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
710
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
625
Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
3.6K