Related Experiment Video
Updated: Jan 27, 2026

03:59
Surgical Correction for Pediatric Epiblepharon and Trichiasis
Published on: July 8, 2025
551
Correction to: A consensus response on the complete picture: reply to Lynøe and Eriksson
Arabinda Kumar Choudhary1, Sandeep K Narang2, Joëlle Anne Moreno3
1Department of Radiology, Nemours/Alfred I. duPont Hospital for Children, 1600 Rockland Road, Wilmington, DE, 19803, USA. ac0026@nemours.org.
Pediatric Radiology
|March 17, 2019
Summary
This paper corrects an error in its original version. The conflict of interest (COI) statement has been updated for accuracy.
Area of Science:
- Scientific publishing ethics
- Research integrity
Background:
- Accurate disclosure of potential conflicts is crucial in scientific research.
- Maintaining transparency in scientific publications is a core ethical principle.
Purpose of the Study:
- To correct an error in the original publication.
- To provide an accurate conflict of interest (COI) statement.
Main Methods:
- Review of the original manuscript.
- Correction of the conflict of interest disclosure.
Main Results:
- The original COI statement was identified as incorrect.
- An accurate COI statement has been provided.
Conclusions:
- Correction ensures adherence to ethical publishing standards.
- Accurate COI statements are vital for research credibility.
Related Concept Videos
Distance Corrections
282
To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
282
Power Factor Correction
528
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
528
NMR Spectrometers: Resolution and Error Correction
1.1K
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K
Responses to Gravity and Touch
41.9K
Gravitropism: Plant Responses to Gravity
41.9K
Humoral Immune Responses
83.8K
Overview
83.8K
Responses to Drought and Flooding
12.0K
Water plays a significant role in the life cycle of plants. However, insufficient or excess of water can be detrimental and pose a serious threat to plants.
12.0K

