Abstract:
Energy-efficient building refurbishment has the aim of saving energy and thus reducing CO2 emissions. Increased energy efficiency of a building often implies reduced air exchange. Together with other indoor air quality problems, this may lead to an increase in indoor radon concentration (Rn-222). In order to investigate the extent of this problem, measurements of radon concentration in energy-efficient refurbished and low-energy houses (passive houses) were carried out. Track etch detectors were exposed in each type of building over a period of 1 year. A reference sample of non-refurbished non-passive buildings was drawn from the National Radon Database for comparison. Buildings were selected that have the same radon relevant properties and were built on comparable geological subsoil like those investigated. The reference sample was compiled in such a way that the measured values from the rooms on the ground floor of the refurbished and passive houses were each assigned a measured value from the database. The statistical analysis shows that the houses refurbished for energy efficiency have a wider distribution of radon concentrations indoors than the non-refurbished ones. Both the mean value and the median of the radon concentration have nearly doubled in buildings refurbished for energy efficiency. The difference is statistically significant. On the other hand, there is no significant difference between the distributions of passive houses and houses not refurbished for energy efficiency.
More Related Videos
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Free Energy
What is Energy?