A patient-specific mass-spring model for biomechanical simulation of aortic root tissue during transcatheter aortic
Alessandro Cristoforetti1,2, Michela Masè2,3, Roberto Bonmassari4
1Department of Industrial Engineering, University of Trento, Trento, Italy.
Abstract:
The success of transcatheter aortic valve implantation (TAVI) is highly dependent on the prediction of the interaction between the prosthesis and the aortic root anatomy. The simulation of the surgical procedure may be useful to guide artificial valve selection and delivery, nevertheless the introduction of simulation models into the clinical workflow is often hindered by model complexity and computational burden. To address this point, we introduced a patient-specific mass-spring model (MSM) with viscous damping, as a good trade-off between simulation accuracy and time-efficiency. The anatomical model consisted of a hexahedral mesh, segmented from pre-procedural patient-specific cardiac computer tomographic (CT) images of the aortic root, including valve leaflets and attached calcifications. Nodal forces were represented by linear-elastic springs acting on edges and angles. A fast integration approach based on the modulation of nodal masses was also tested. The model was validated on seven patients, comparing simulation results with post-procedural CT images with respect to calcification and aortic wall position. The validation showed that the MSM was able to predict calcification displacement with an average accuracy of 1.72 mm and 1.54 mm for the normal and fast integration approaches, respectively. Wall displacement root mean squared error after valve expansion was about 1 mm for both approaches, showing an improved matching with respect to the pre-procedural configuration. In terms of computational burden, the fast integration approach allowed a consistent reduction of the computational times, which decreased from 36 h to 21.8 min per 100 K hexahedra. Our findings suggest that the proposed linear-elastic MSM model may provide good accuracy and reduced computational times for TAVI simulations, fostering its inclusion in clinical routines.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Frequency of Spring-Mass System
Consider a block on a spring on a frictionless surface. There...
Aortic Regurgitation I: Introduction
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Primary and Secondary Growth in Roots and Shoots