Related Experiment Video
Updated: Jan 27, 2026

18F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
Quantitative estimation of extravascular lung water volume and preload by dynamic 15O-water positron emission
Roni Ranghøj Nielsen1,2, Jens Sörensen2,3,4, Lars Tolbod3
1Department of Cardiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, Aarhus DK, Denmark.
Aims:
Left ventricular filling pressure (preload) can be assessed by pulmonary capillary wedge pressure (PCWP) during pulmonary arterial catheterization (PAC). An emerging method [pulse indexed contour cardiac output (PICCO)] can estimate preload by global end-diastolic volume (GEDV) and congestion as extravascular lung water (EVLW) content. However, no reliable quantitative non-invasive methods are available. Hence, in a porcine model of pulmonary congestion, we evaluated EVLW and GEDV by positron emission tomography (PET). The method was applied in 35 heart failure (HF) patients and 9 healthy volunteers.
Methods And Results:
Eight pigs were studied. Pulmonary congestion was induced by a combination of beta-blockers, angiotensin-2 agonist and saline infusion. PAC, PICCO, computerized tomography, and 15O-H2O-PET were performed. EVLW increased from 521 ± 76 to 973 ± 325 mL (P < 0.001) and GEDV from 1068 ± 170 to 1254 ± 85 mL (P < 0.001). 15O-H2O-PET measures of EVLW increased from 566 ± 151 to 797 ± 231 mL (P < 0.001) and GEDV from 364 ± 60 to 524 ± 92 mL (P < 0.001). Both EVLW and GEDV measured with PICCO and 15O-H2O-PET correlated (r2 = 0.40, P < 0.001; r2 = 0.40, P < 0.001, respectively). EVLW correlated with Hounsfield units (HU; PICCO: r2 = 0.36, P < 0.001, PET: r2 = 0.46, P < 0.001) and GEDV with PCWP (PICCO: r2 = 0.20, P = 0.01, PET: r2 = 0.29, P = 0.002). In human subjects, measurements were indexed (I) for body surface area. Neither EVLWI nor HU differed between chronic stable HF patients and healthy volunteers (P = 0.11, P = 0.29) whereas GEDVI was increased in HF patients (336 ± 66 mL/m2 vs. 276 ± 44 mL/m2, P = 0.01).
Conclusion:
The present study demonstrates that 15O-H2O-PET can assess pulmonary congestion and preload quantitatively. Hence, prognostic information from 15O-H2O-PET examinations should be evaluated in clinical trials.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...
Quality of Water
Water and Mineral Acquisition
The Water Cycle

