An in vitro comparison of flow dynamics of the Magna Ease and the Trifecta prostheses
Philipp Marx1, Wojciech Kowalczyk2, Aydin Demircioglu3
1Department of Thoracic and Cardiovascular Surgery, West-German Heart and Vascular Center Essen, University Hospital Essen, Essen, Germany.
Abstract:
Objectives: We aimed to compare the in vitro flow dynamics of the Perimount Magna Ease™ (PME) and the Trifecta™ (TF) bioprostheses.Material and methods: A new flow chamber was designed to compare the flow patterns of the PME (Edwards Lifesciences, Irvine, CA, USA) and the TF (SJM, St. Paul, MN, USA) aortic valve prostheses. This new channel offered the possibility of 2D-particle-image-velocimetry (2D-PIV) to completely evaluate the flow field downstream from the aortic valve to the middle of the aortic arch. Maximum average velocities, vorticity, shear strength, maximum orifice diameters and jet flow diameters were analyzed. Valve sizes of 21, 23 and 25 mm were evaluated.Results: Average velocity values, shear strength and vorticities were smaller in the flow field of the TF (maximum average velocity: 0.81 ± 0.03m/s, PME 23 mm vs. 0.7 ± 0.02m/s TF 23 mm, P < .001) under pulsatile flow conditions (70 Hz, 70 mL stroke volume). The evaluation of the upper orifice area revealed bigger maximum diameters during the peak flow phase for the TF, but more leaflet-flutter.Conclusions: Our flow chamber allowed a precise and highly sensitive characterization and comparison of complex fluid dynamics of different aortic valve prostheses. Both the Trifecta™ and the Perimount Magna Ease™ showed a good performance on a high level.
More Related Videos
06:24Paired Cisterna Magna Nanoinjection and Laser Speckle Contrast Imaging Assay to Study Cerebral Blood Flow Regulation In Vivo
Published on: July 8, 2025
05:21Characterization of the Sense of Agency over the Actions of Neural-machine Interface-operated Prostheses
Published on: January 7, 2019
Related Concept Videos
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Molecular Comparison of Gases, Liquids, and Solids
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits