Related Experiment Video
Updated: Jan 27, 2026

Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Range-ambiguity artifact in abdominal ultrasound
Hiroko Naganuma1, Hideaki Ishida2, Hiroshi Nagai3
1Department of Gastroenterology, Yokote Municipal Hospital, 5-31 Negishi-cho, Yokote, Akita, 013-8602, Japan. hiron@vesta.ocn.ne.jp.
Abstract:
Range-ambiguity artifacts (RAAs) are an erroneous mapping of returning echoes into a composite picture. The purpose of this review was to illustrate the mechanism of RAAs and to present the diagnostic problems caused by RAAs. RAA features differ slightly from organ to organ. At the level of the urinary bladder, RAAs take the form of a cloud-like, ill-demarcated, immobile, echogenic area, and the depth of the echogenic area differs depending on the pulse repetition frequency (PRF). This form is referred to as "static RAA" in this review. There are two key ultrasound characteristics of RAAs at the level of the liver: (a) the depth of RAAs change according to the PRF, and (b) RAAs move in accordance with the cardiac cycle. This form is referred to as "mobile RAA" in this review. At the level of the gallbladder, RAAs take the form of fine echogenic lines in the gallbladder. This phenomenon is actually a combination of two phenomena: a ring-down artifact and RAA. This form is referred to as "complex RAA (searchlight phenomenon)" in this review. The easiest way to reduce RAAs is to change the image depth. Sufficient knowledge of RAAs can prevent misdiagnosis of erroneously displayed returning echoes as real pathologic changes.
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...