Effect of planting patterns on yield, nutrient accumulation and distribution in maize and soybean under relay

Muhammad Ali Raza1,2, Muhammad Hayder Bin Khalid1,3, Xia Zhang1,2

  • 1College of Agronomy, Sichuan Agricultural University, Chengdu, Sichuan, 611130, China.

Scientific Reports
|March 22, 2019
PubMed

Related Concept Videos

Plant Breeding and Biotechnology01:59

Plant Breeding and Biotechnology

Crop cultivation has a long history in human civilization, with records showing the cultivation of cereal plants beginning at around 8000 BC. This early plant breeding was developed primarily to provide a steady supply of food.
21.7K
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
612
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
533
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
763
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
446
ATP Yield01:31

ATP Yield

Cellular respiration produces 30 - 32 ATP per glucose molecule. Although most of the ATP results from oxidative phosphorylation and the electron transport chain (ETC), 4 ATP are gained beforehand (2 from glycolysis and 2 from the citric acid cycle).
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
78.8K