Related Experiment Video
Updated: Jan 27, 2026

Systematic Approach to Identify Novel Antimicrobial and Antibiofilm Molecules from Plants' Extracts and Fractions to Prevent Dental Caries
Published on: March 31, 2021
Comparison of different caries detectors for approximal caries detection
Esin Bozdemir1, Ali Murat Aktan2, Abdulsemih Ozsevik3
1Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Suleyman Demirel University, Isparta, Turkey.
Background/Purpose:
Detection of approximal caries may be difficult using conventional methods including visual inspection (VI) and radiography. The purpose of this in vitro research was to evaluate the efficiency of light-emitting diode (LED) and laser fluorescence (LF) devices, and radiographic and visual examination in approximal caries diagnosis.
Materials And Methods:
One hundred and fifty-six approximal regions were evaluated. All approximal regions were investigated using LED and LF tools after radiography and VI were performed. Histological evaluation of teeth was performed using stereomicroscopy. The area under the receiver operating characteristic curve and accuracy, specificity, sensitivity values calculated regarding approximal caries diagnose.
Results:
The specificity of the bitewing examination was higher for both T1 and T2 thresholds (0.97 and 0.99, respectively), and the LF device showed better sensitivity at each threshold compared with the other devices used for caries diagnosis (0.94 at T1 and 0.79 at T2). The receiver operating characteristic curves presented that the LF device was more successful than the other techniques at T1 threshold and VI was better than the other caries detection methods at T2 threshold. The kappa values for interobserver agreements were 0.43 (LF pen), 0.33 (LED device), 0.55 (VI), and 0.75 (bitewing examination).
Conclusion:
The ability of bitewing radiography to identify sound surfaces was better than that of the other methods. The LF device was the most sensitive tool for detecting approximal surfaces with caries, followed by the LED device.
Related Concept Videos
Linearization and Approximation
Application of Linearization and Approximation
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...

