Related Experiment Video
Updated: Jan 27, 2026

A Uniaxial Compression Experiment with CO2-Bearing Coal Using a Visualized and Constant-Volume Gas-Solid Coupling Test System
Published on: June 12, 2019
A viscoelastic nonlinear compressible material model of lung parenchyma - Experiments and numerical identification
Anna M Birzle1, Wolfgang A Wall1
1Institute for Computational Mechanics, Technical University of Munich, Boltzmannstr. 15, 85747 Garching b. München, Germany.
Abstract:
Characterizing material properties of lung parenchyma is essential in order to describe and predict the mechanical behavior of the lung in health and disease. Hence, we aim to identify the viscoelastic constitutive behavior of viable lung parenchyma with a particular focus on the nonlinear, compressible, and frequency-dependent material properties. To quantify the viscoelastic material behavior of rat lung parenchyma experimentally, we performed uniaxial tension tests with different frequencies, including the whole range of physiological frequencies, in combination with full-field displacement measurements (a total of 120 tests on 30 samples of 5 rats). By means of these experimental measurements, we identified the material parameters of two viscoelastic material models applicable to large three-dimensional deformations, i.e., the standard linear solid model and the model of fractional viscoelasticity. Our aim is to identify one set of material parameters that describes the whole range of physiological frequencies; therefore, we utilized a coupled inverse analysis, which equally incorporates all different tensile tests performed on one sample. The model most suitable for the description of the viscoelastic, nonlinear, and compressible material behavior of viable rat lung parenchyma is the strain energy function [Formula: see text] in combination with the model of fractional viscoelasticity (τ=0.06454s,α=0.5378, and β=1.856). This material model was validated to describe the complex nonlinear and compressible viscoelastic material behavior of lung parenchyma and can be utilized in finite element simulations of the whole range of physiological frequencies. Based on this model, it will be possible to quantify the stresses and strains of lung tissue during spontaneous and artificial breathing more reliable in the future.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Numerical Calculations
The solution to a problem is obtained using different methods. While manually solving algebraic symbols is one of the most common methods, the graphical method is often preferred. Computers...
Pilot and Numeric Relaying
Drug Distribution as One-Compartment Model and Elimination by Nonlinear Pharmacokinetics: Overview
For instance, consider the metabolism of sodium salicylate. This compound is metabolized into two distinct substances: a glucuronide and a glycine conjugate. The rate of conjugation depends...
How Data are Classified: Numerical Data
Quantitative data may be either discrete or continuous. All quantitative data that take on only specific numerical...

