Background:
Many surgeons utilize assistants to perform procedures in more than one operating room at a given time using a practice known as overlapping surgery. Debate has continued as to whether overlapping surgery improves the efficiency and access to care or risks patient safety and outcomes.
Objective:
To examine effects of overlapping surgery in deep brain stimulation (DBS) for movement disorders.
Methods:
In this retrospective analysis of overlapping and non-overlapping cases, we evaluated stereotactic accuracy, operative duration, length of hospital stay, and the presence of hemorrhage, wound-related complications, and hardware-related complications requiring revision in adults with movement disorders undergoing DBS.
Results:
Of 324 cases, 141 (43.5%) were overlapping and 183 (56.5%) non-overlapping. Stereotactic error, number of brain penetrations, and postoperative length of hospitalization did not differ significantly (p ≥ 0.08) between the overlapping and non-overlapping groups. Mean operative duration was significantly longer for overlapping (81/141 [57.4%], 189.5 ± 10.8 min) than for non-overlapping cases (79/183 [43.2%], 169.9 ± 7.6 min; p = 0.004). There were no differences in rates of wound-related complications or hemorrhages, but overlapping cases had a significantly higher rate of hardware-related complications requiring revision (7/141 [5.0%] vs. 0/183 [0%]; p = 0.002).
Conclusions:
Overlapping and non-overlapping cases had comparable DBS lead placement accuracy. Overlapping cases had a longer operative duration and had a higher rate of hardware-related complications requiring revision.
More Related Videos
09:46Analysis of Gene Expression Changes in the Rat Hippocampus After Deep Brain Stimulation of the Anterior Thalamic Nucleus
Published on: March 8, 2015
09:36In vivo Positron Emission Tomography to Reveal Activity Patterns Induced by Deep Brain Stimulation in Rats
Published on: March 23, 2022
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error