Related Experiment Video
Updated: Jan 27, 2026

Effects of a Novel Neuromuscular Training Intervention on Jump, Sprint, and Change of Direction in Adult Female Soccer Players
Published on: June 10, 2025
Can we use GPS for assessing sprinting performance in rugby sevens? A concurrent validity and between-device
Mathieu Lacome1,2, Alexis Peeters1, Bertrand Mathieu1
1Research Department, French Rugby Union, Marcoussis, France.
Abstract:
The purpose of this study was to (1) provide data on maximal sprinting speed (MSS) and maximal acceleration (Amax) in elite rugby sevens players measured with GPS devices, (2) test the concurrent validity of the signal derived from a radar device and a commercially available 16 Hz GPS device, and (2) assess the between-device reliability of MSS and Amax of the same GPS. Fifteen elite rugby sevens players (90 ± 12 kg; 181 ± 8 cm; 26 ± 5 y) participated in the maximal sprinting test. A subset of five players participated in the concurrent validity and between-devices reliability study. A concurrent validity protocol compared the GPS units and a radar device (Stalker ATS II). The between-device reliability of the GPS signal during maximal sprint running was also assessed using 6 V2 GPS units (Sensorevery-where, Digital Simulation, Paris, France) attached to a custom-made steel sled and pushed by the five athletes who performed a combined total of 15 linear 40m sprints. CV ranged from 0.5, ±0.1 % for MSS and smoothed MSS to 6.4, ±1.1 % for Amax. TEM was trivial for MSS and smoothed MSS (0.09, ±0.01) and small for Amax and smoothed Amax (0.54, ±0.09 and 0.39, ±0.06 respectively). Mean bias ranged from -1.6, ±1.0 % to -3.0, ±1.1 % for smoothed MSS and MSS respectively. TEE were small (2.0, ±0.55 to 1.6, ±0.4 %, for MSS and smoothed MSS respectively. The main results indicate that the GPS units were highly reliable for assessing MSS and provided acceptable signal to noise ratio for measuring Amax, especially when a smoothing 0.5-s moving average is used. This 16 Hz GPS device provides sport scientists and coaches with an accurate and reliable means to monitor running performance in elite rugby sevens.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
09:18Feeding Experimentation Device FED: Construction and Validation of an Open-source Device for Measuring Food Intake in Rodents
Published on: February 21, 2017
Related Concept Videos
Reliability and Validity
Distribution Reliability and Automation
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include:
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...